{"product_id":"pw482-s01-power-supply-module-yokogawa","title":"PW482-S01 Power Supply Module | Yokogawa","description":"\u003ch2\u003eYokogawa PW482-S01 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa PW482-S01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW482\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for AC-to-DC power conversion and internal power distribution within CENTUM VP and CENTUM CS 3000 control system architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSuffix Code\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-5\u003c\/td\u003e\n\u003ctd\u003eStandard type, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-E\u003c\/td\u003e\n\u003ctd\u003eStandard type with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option with operating temperature range of -20 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW482-S01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220 to 240 VAC +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e199.5 mm x 49.7 mm x 146.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 degC to 70 degC (suffix dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Slot\u003c\/td\u003e\n\u003ctd\u003eP1 to P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual module configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eExclusive system connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Power Distribution Characteristics\u003c\/h3\u003e\n\u003cp\u003eWithin Yokogawa DCS architectures, the PW482-S01 provides regulated 24 VDC system power to connected control assemblies through dedicated backplane interfaces. The module is intended for installation in FCU, FIO Node Unit, and Optical ESB Bus Repeater platforms where internal power segregation and controlled distribution paths are required.\u003c\/p\u003e\n\u003cp\u003eDual-module installation enables redundant power operation by mounting identical PW482 units in designated power slots. Power transfer and load sharing behavior are managed by the host system hardware architecture. The module does not provide general-purpose field wiring terminals and is designed exclusively for compatible Yokogawa system assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the PW482-S01 operate in a redundant configuration?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Redundant operation is achieved by installing two identical PW482 modules in the designated P1 and P2 power slots of compatible Yokogawa hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the PW482-S01 a general-purpose 24 VDC power supply?\u003c\/strong\u003e\u003cbr\u003eA: No. The module uses a system-specific connector and is designed exclusively for compatible CENTUM VP and CENTUM CS 3000 platform assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which slot is required for a single power supply installation?\u003c\/strong\u003e\u003cbr\u003eA: In a non-redundant configuration, the module must be installed in slot P1 according to Yokogawa installation requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify compatibility with the target FCU, FIO Node Unit, or Optical ESB Bus Repeater Unit before installation.\u003c\/li\u003e\n\u003cli\u003eFor single power configurations, install the module in slot P1 only.\u003c\/li\u003e\n\u003cli\u003eFor redundant power configurations, install two identical PW482 modules in slots P1 and P2.\u003c\/li\u003e\n\u003cli\u003eRemove input power before inserting or removing the module unless the host system documentation explicitly permits energized replacement procedures.\u003c\/li\u003e\n\u003cli\u003eEnsure cabinet grounding conforms to site electrical standards and DCS grounding practices.\u003c\/li\u003e\n\u003cli\u003eRoute AC input conductors separately from low-level signal wiring to minimize conducted electrical interference.\u003c\/li\u003e\n\u003cli\u003eConfirm input voltage and frequency are within the specified operating range before energization.\u003c\/li\u003e\n\u003cli\u003eInspect module connectors and backplane interfaces for contamination or mechanical damage prior to installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44219001307224,"sku":"PW482-S01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/PW482-S01-3.jpg?v=1781141372","url":"https:\/\/www.industriaxplc.com\/ar\/products\/pw482-s01-power-supply-module-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}