{"product_id":"nfcp100-s05-field-control-processor-module-yokogawa","title":"NFCP100-S05 Field Control Processor Module | Yokogawa","description":"\u003ch2\u003eYokogawa NFCP100-S05 Field Control Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for regulatory control, sequence control, and data computation tasks in CENTUM DCS platforms, the \u003cstrong\u003eYokogawa NFCP100-S05\u003c\/strong\u003e (\u003cstrong\u003eNFCP100\u003c\/strong\u003e Field Control Processor Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFCP100-S05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Loop Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 200 regulatory control loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eHigh-speed RISC processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003eECC RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration (hot-standby)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Network Interface\u003c\/td\u003e\n\u003ctd\u003eV net or Vnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Bus Connection\u003c\/td\u003e\n\u003ctd\u003eESB or ER bus master modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 VA to 20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSlot-mounted within dedicated FCU nest\/chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.8 kg to 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa proprietary card form factor for FCU slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 degC to +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Features\u003c\/h3\u003e\n\u003cp\u003eThe NFCP100-S05 incorporates channel-to-channel isolation parameters across its interface circuitry to prevent ground loops from degrading signal integrity. When communicating with process instrumentation over field networks, the processor manages digital data synchronization across 4-20 mA HART loop protocol configurations and FOUNDATION Fieldbus\/Profibus PA connectivity matrices via connected interface modules. The internal processing architecture executes hardware-driven cold junction compensation (CJC) equations for high-density thermocouple input processing, maintaining deterministic scan periods down to the millisecond level across all distributed field control unit nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum switchover latency during a dual-redundant processor failure event?\u003c\/p\u003e\n\u003cp\u003eA: The hardware-driven hot-standby switchover mechanism transfers control to the redundant backup partner module in less than a few milliseconds, ensuring zero interruption to the running control loops.\u003c\/p\u003e\n\u003cp\u003eQ: Does the NFCP100-S05 require forced-air cooling within the Field Control Unit chassis?\u003c\/p\u003e\n\u003cp\u003eA: No. The module is engineered with low heat dissipation components, allowing natural convection cooling and eliminating the requirement for an internal cooling fan.\u003c\/p\u003e\n\u003cp\u003eQ: Can an online module replacement be executed during active process operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware architecture supports online maintenance and hot-swapping, allowing a faulty processor module to be extracted and replaced while its redundant partner maintains active control of the process network.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Insert the module vertically into the dedicated Field Control Unit (FCU) slot guide rails. Ensure the rear card-edge connectors align precisely with the backplane receptacle before applying insertion force.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Secure the module faceplate retaining screws to the chassis frame to establish a low-impedance electrical ground pathway. The field control nest must be tied to a single-point instrument ground system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route the V net\/Vnet\/IP communication cables and ESB bus connections in separate wire ways isolated from high-voltage AC power distribution lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44182063743064,"sku":"NFCP100-S05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/NFCP100-S05.jpg?v=1780540565","url":"https:\/\/www.industriaxplc.com\/ar\/products\/nfcp100-s05-field-control-processor-module-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}