{"product_id":"mu-mc-taih12-51304337-100-analog-input-modules-honeywell","title":"MU\/MC-TAIH12 51304337-100 | Analog Input Modules | Honeywell","description":"\u003ch2\u003eHoneywell MC-TAIH12 High-Level Analog Input Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-level analog signal termination in Honeywell Experion PKS and TDC 3000 DCS platforms, the \u003cstrong\u003eHoneywell MC-TAIH12-51304337-100\u003c\/strong\u003e (\u003cstrong\u003eMC-TAIH12\u003c\/strong\u003e High-Level Analog Input Termination Assembly) provides direct physical and electrical execution between field instruments and I\/O processing hardware.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Termination Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304337-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input, typically 4-20 mA or 1-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS and TDC 3000 DCS platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eYes, MC series protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupports redundant I\/O configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eFTA mounting channel \/ DIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Interface and Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAIH12 provides field-side termination for analog measurement circuits connected to Honeywell I\/O processors. Moreover, the assembly routes 4-20 mA and voltage input signals through dedicated termination points while maintaining separation between field wiring and control electronics.\u003c\/p\u003e\n\u003cp\u003eThe FTA design supports channel-to-channel isolation functions that reduce electrical interference between individual analog loops. In addition, the conformal coated circuit assembly protects electronic components against moisture, dust, and airborne industrial contaminants.\u003c\/p\u003e\n\u003cp\u003eFor process instrumentation applications, the module interfaces with transmitter-based measurement loops using standard analog signal practices. Therefore, correct shield termination and grounding methods are required to maintain signal accuracy.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MC-TAIH12 support 16 analog input channels?\u003cbr\u003eA: Yes. The MC-TAIH12 provides termination capability for 16 high-level analog input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field signals can connect to the MC-TAIH12?\u003cbr\u003eA: The assembly supports high-level analog input signals, including typical 4-20 mA and 1-5 VDC transmitter outputs.\u003c\/p\u003e\n\u003cp\u003eQ: Is the MC-TAIH12 designed for installation in harsh industrial environments?\u003cbr\u003eA: Yes. The conformal coated construction provides additional protection for electronic circuits against environmental contaminants.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MC-TAIH12 on the designated FTA mounting channel or approved DIN rail assembly.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity before connecting analog input terminals to prevent signal inversion.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cables for low-level analog measurement circuits where required.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding standard to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm compatibility between the FTA terminal assignment and the associated Honeywell I\/O module before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44376056004696,"sku":"MU\/MC-TAIH12 51304337-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MUMC-TAIH1251304337-100-3.jpg?v=1784014597","url":"https:\/\/www.industriaxplc.com\/ar\/products\/mu-mc-taih12-51304337-100-analog-input-modules-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}