{"product_id":"is200tbcih1bce-ge-contact-input-terminal-board","title":"IS200TBCIH1BCE GE Contact Input Terminal Board","description":"\u003ch2\u003eGE IS200TBCIH1BCE Contact Input Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TBCIH1BCE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TBCIH1BCE\u003c\/strong\u003e Contact Input Terminal Board, operates as a dedicated hardware component for discrete signal acquisition within the GE Mark VI\/VIe Speedtronic turbine control system. The board interfaces field contact devices through isolated input channels, providing conditioned electrical signals for turbine monitoring and protection logic execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBCIH1BCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eContact Input Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI \/ Mark VIe Speedtronic Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTBCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision 1\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision 2\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArtwork Revision\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Inputs\u003c\/td\u003e\n\u003ctd\u003e24 isolated channels, simplex configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal, 18 to 32 VDC operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical\/electrical isolation between channels and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Suppression\u003c\/td\u003e\n\u003ctd\u003eEMI and surge transient filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection\u003c\/td\u003e\n\u003ctd\u003eBarrier terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eChannel health monitoring and fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VI rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware and Industrial Control Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBCIH1BCE provides discrete input conditioning for GE Mark VI\/VIe control architectures. The terminal board supports isolated contact signal routing between field devices and turbine controller I\/O processing assemblies. The design uses channel-level electrical isolation and filtering functions to reduce interference effects from field wiring environments.\u003c\/p\u003e\n\u003cp\u003eThe board configuration supports deterministic contact state acquisition for turbine protection and control sequences. Its hardware interface is compatible with switches, protective relay contacts, and other dry-contact field devices connected through Mark VI\/VIe terminal assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signals can the IS200TBCIH1BCE process?\u003cbr\u003eA: The IS200TBCIH1BCE processes discrete contact input signals from field devices such as switches, sensors, and protective relay contacts through isolated input channels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the terminal board provide electrical isolation between input channels?\u003cbr\u003eA: Yes. The board provides optical\/electrical isolation between input channels and ground to separate field wiring signals from controller-side circuits.\u003c\/p\u003e\n\u003cp\u003eQ: What installation considerations apply to field wiring connections?\u003cbr\u003eA: Field wiring should maintain proper separation from high-voltage conductors, use appropriate shielding practices where required, and follow GE Mark VI\/VIe cabinet wiring guidelines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200TBCIH1BCE in the designated GE Mark VI\/VIe rack position and verify mechanical seating before connecting field wiring.\u003c\/p\u003e\n\u003cp\u003eUse terminal wiring practices suitable for industrial control environments. Maintain separation between discrete signal cables and high-energy power conductors to minimize electromagnetic interference. Where shielded cables are used, connect shields according to the grounding requirements of the control cabinet design.\u003c\/p\u003e\n\u003cp\u003eVerify contact input polarity, field voltage levels, and terminal assignments before energizing the circuit. Confirm channel diagnostics after installation to validate correct field device connections and signal acquisition.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44407845388376,"sku":"IS200TBCIH1BCE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200TBCIH2C_3591f172-1d84-4525-8374-a48601a518e2.jpg?v=1784625745","url":"https:\/\/www.industriaxplc.com\/ar\/products\/is200tbcih1bce-ge-contact-input-terminal-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}