{"product_id":"is200gdddg1aba-ge-ex2100-gate-driver-board","title":"IS200GDDDG1ABA GE EX2100 Gate Driver Board","description":"\u003ch2\u003eGE IS200GDDDG1ABA Gate Driver Dynamic Discharge Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200GDDDG1ABA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200GDDDG1ABA\u003c\/strong\u003e Gate Driver Dynamic Discharge Board, operates as a dedicated hardware component for IGBT gate control and DC link energy discharge execution within the GE Mark VI \/ EX2100 excitation control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200GDDDG1ABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 cm high x 33.02 cm wide x 90 mm depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 V at 1.2 A, +\/-12 V at 200 mA from VME backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGate Driver Dynamic Discharge Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ EX2100 Static Exciter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Drive Channels\u003c\/td\u003e\n\u003ctd\u003e6 differential gate drive channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Drive Output\u003c\/td\u003e\n\u003ctd\u003e15 V differential, 2 A peak, 20 us pulse width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Drive Isolation\u003c\/td\u003e\n\u003ctd\u003eTransformer-isolated gate drive circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Discharge Device\u003c\/td\u003e\n\u003ctd\u003e600 V IGBT with 2 kA pulse capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Discharge Response\u003c\/td\u003e\n\u003ctd\u003e10 us turn-on time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 Vrms gate-to-logic, 500 V channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e96-pin DIN VME connector, two 20-position pluggable headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eGate supply UVLO, desaturation detection, MOV surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators for Bridge OK, IMOK, and DD AUX Power Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eIPC-CC-830 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Excitation IGBT Gate Control and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200GDDDG1ABA provides IGBT switching control within the GE Mark VI and EX2100 excitation architecture. The board receives gate commands through the VME backplane interface and generates isolated drive signals for six IGBT devices in the exciter bridge.\u003c\/p\u003e\n\u003cp\u003eThe dynamic discharge circuit manages DC link energy dissipation during fault or shutdown sequences by controlling the discharge IGBT and resistor path. The board supports Mark VI TMR architecture compatibility, allowing synchronized control processing across redundant controller channels.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility with the Mark VI control environment allows diagnostic communication and hardware status monitoring. Protection circuits including undervoltage lockout, desaturation detection, and surge suppression monitor gate drive conditions during switching operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many IGBT gate drive channels are provided by the IS200GDDDG1ABA?\u003cbr\u003eA: The board provides six isolated differential gate drive channels for IGBT bridge control.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the dynamic discharge function?\u003cbr\u003eA: The dynamic discharge circuit transfers stored DC link energy into resistor banks during trip or shutdown events to control overvoltage conditions.\u003c\/p\u003e\n\u003cp\u003eQ: What interface connects the board to the Mark VI controller system?\u003cbr\u003eA: The board uses a 96-pin DIN VME connector and additional pluggable headers for system interfacing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200GDDDG1ABA in the designated GE Mark VI or EX2100 VME rack position with correct connector alignment. Verify that all excitation power sources and DC link circuits are de-energized before installation or replacement.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between gate drive wiring, high-voltage DC conductors, and low-level control wiring. Ensure cabinet grounding and shielding connections follow the excitation system installation requirements to minimize electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eCheck VME connector seating, auxiliary power connections, and diagnostic LED status after installation. Verify gate drive signal integrity and system communication before returning the excitation system to service.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44387537944664,"sku":"IS200GDDDG1ABA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200EBRGH2A_de1a4f5f-0fc5-4abd-b062-92cccea0d120.jpg?v=1784186827","url":"https:\/\/www.industriaxplc.com\/ar\/products\/is200gdddg1aba-ge-ex2100-gate-driver-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}