{"product_id":"is200acleh1caa-ge-mark-vi-application-control-module","title":"IS200ACLEH1CAA GE Mark VI Application Control Module","description":"\u003ch2\u003eGE IS200ACLEH1CAA Application Control Layer Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200ACLEH1CAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200ACLEH1CAA\u003c\/strong\u003e Application Control Layer Module, operates as a dedicated hardware component for deterministic excitation control execution within GE Mark VI and EX2100 Excitation Control Systems. The module provides processor-based task management, communication handling, and control processing through a 100 MHz CPU, onboard memory, and system interface channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1CAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eApplication Control Layer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMark VI \/ EX2100 Excitation Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel 486 CPU, 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e8 MB DRAM, 4 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCache\u003c\/td\u003e\n\u003ctd\u003e128 KB L2 cache\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, ISBus, COM1\/COM2 serial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or exciter backplane slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Control and Firmware Execution\u003c\/h3\u003e\n\u003cp\u003eThe IS200ACLEH1CAA uses a microprocessor-based architecture for execution of excitation control tasks, communication processing, and system synchronization functions. The 4 MB Flash memory stores firmware and configuration data, while the DRAM supports runtime processing requirements. The module manages Ethernet communication, ISBus synchronization, and serial interface operations within the Mark VI control architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are supported by the IS200ACLEH1CAA?\u003cbr\u003eA: The module supports Ethernet, ISBus, and COM1\/COM2 serial communication interfaces for control system data exchange and diagnostics.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply requirements apply to this module?\u003cbr\u003eA: The module operates with a 125 VDC input system interface and uses a 5 VDC backplane supply for internal module operation.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IS200ACLEH1CAA compatible with EX2100 excitation systems?\u003cbr\u003eA: The module is designed for installation in GE EX2100 exciter racks and Mark VI control system architectures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eVerify cabinet power isolation before module replacement or installation. Use ESD protection equipment when handling the circuit board assembly. Install the module into the assigned exciter backplane slot or DIN-rail mounting position according to rack configuration requirements.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet, ISBus, and serial cables separately from high-voltage power conductors to reduce electromagnetic interference. Ensure cable shielding is connected according to cabinet grounding practices. Confirm backplane seating, connector engagement, and firmware compatibility before system energization.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44415680217176,"sku":"IS200ACLEH1CAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200ACLEH1CAA_b960b36b-d525-42be-8924-151e48de8b53.jpg?v=1784709244","url":"https:\/\/www.industriaxplc.com\/ar\/products\/is200acleh1caa-ge-mark-vi-application-control-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}