{"product_id":"ics-triplex-tc-301-02-2m5-trusted-system-communication-cable-assembly","title":"ICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly","description":"\u003ch2\u003eICS Triplex TC-301-02-2M5 Trusted System Communication Cable Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eICS Triplex TC-301-02-2M5\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-301-02-2M5\u003c\/strong\u003e Trusted System Communication Cable Assembly, operates as a dedicated hardware component for TMR communication signal transfer within the ICS Triplex Trusted Safety System. It provides physical interconnection between Trusted processor expansion interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-301-02-2M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTrusted System Communication \/ Expansion Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eScreened Category 6 Plus cable with LSZH outer sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Side Connector\u003c\/td\u003e\n\u003ctd\u003e96-way Type C connector with integrated earth braid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter Side Connector\u003c\/td\u003e\n\u003ctd\u003e12-way LEMO plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003eTrusted proprietary TMR expansion communication bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003e360-degree EMI and RFI shielding structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.85 kg to 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCable assembly, 2.5 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-5 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cable assembly, no independent power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Safety Communication Interface\u003c\/h3\u003e\n\u003cp\u003eThe TC-301-02-2M5 cable assembly supports the ICS Triplex Trusted triple modular redundancy communication architecture. It transfers synchronized data signals between Trusted system expansion components, such as the Trusted Expander Processor and Expander Interface Adapter.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the cable maintains signal integrity through a screened construction and dedicated grounding path. The integrated shielding structure reduces electromagnetic interference during operation and supports stable TMR data exchange between redundant hardware nodes.\u003c\/p\u003e\n\u003cp\u003eThe Trusted platform uses a 2oo3 voting architecture to execute fault-tolerant safety functions. Therefore, the TC-301-02-2M5 provides the physical communication path required for coordinated triplicated signal handling within SIL3 safety applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What components does the TC-301-02-2M5 connect within the Trusted system?\u003cbr\u003eA: The TC-301-02-2M5 connects Trusted expansion communication interfaces, typically linking a Trusted Expander Processor with an Expander Interface Adapter through the proprietary TMR bus.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TC-301-02-2M5 require external power input?\u003cbr\u003eA: No. The TC-301-02-2M5 is a passive communication cable assembly and does not include active electronic circuits or independent power requirements.\u003c\/p\u003e\n\u003cp\u003eQ: How should the cable shielding be installed?\u003cbr\u003eA: The cable shielding and earth braid should maintain proper grounding continuity according to the Trusted system installation requirements. Avoid routing the cable parallel to high-current power conductors to reduce electromagnetic coupling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TC-301-02-2M5 according to the Trusted system hardware installation manual and approved cabinet wiring practices.\u003c\/li\u003e\n\u003cli\u003eVerify that both connector interfaces are fully seated before system commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain the cable bend radius specified for the cable construction to prevent mechanical stress on connectors and shielding layers.\u003c\/li\u003e\n\u003cli\u003eConnect the integrated earth braid according to the cabinet grounding scheme.\u003c\/li\u003e\n\u003cli\u003eSeparate communication cable routing from high-voltage and high-current wiring where possible.\u003c\/li\u003e\n\u003cli\u003eInspect connector contacts for contamination, mechanical damage, or improper engagement before installation.\u003c\/li\u003e\n\u003cli\u003eDo not modify connector assemblies or cable shielding structures in the field.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44551537655896,"sku":"TC-301-02-2M5","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-301-02-2M5-2_1200x1200_f4821076-44b2-443d-9d87-7708e6c3bb24.jpg?v=1786434113","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ics-triplex-tc-301-02-2m5-trusted-system-communication-cable-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}