{"product_id":"ics-triplex-t8513-output-module","title":"ICS Triplex T8513 Output Module","description":"\u003ch2\u003eICS Triplex T8513 Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC output switching in the Trusted safety control architecture, the \u003cstrong\u003eICS Triplex T8513\u003c\/strong\u003e (\u003cstrong\u003eT8513\u003c\/strong\u003e Output Module) provides direct electrical execution for connected field circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8513\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOutput Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.8 kg - 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Safety Architecture and Electrical Isolation\u003c\/h3\u003e\n\u003cp\u003eThe ICS Triplex T8513 operates within safety control architectures that use fault-tolerant processing and I\/O arrangements. The supplied data specifies 500 V isolation and a 24 VDC output with a 1 A current rating. Therefore, system designers should verify the installed chassis configuration, field wiring arrangement, and applicable TMR architecture before commissioning.\u003c\/p\u003e\n\u003cp\u003eThe module applies electrical isolation between the output circuit and associated control electronics. In addition, the 24 VDC output rating defines the stated field-side operating voltage, while the 1 A rating defines the supplied maximum output current in the provided specifications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output voltage does the T8513 provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications identify a 24 VDC output with a stated 1 A output current rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What isolation value does the T8513 specification provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data specifies 500 V isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What environmental temperature range is specified for operation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied operating range is 0 deg C to 55 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated ICS Triplex system chassis and follow the applicable chassis installation documentation.\u003c\/li\u003e\n\u003cli\u003eVerify that the field supply voltage matches the specified 24 VDC output configuration before connecting field loads.\u003c\/li\u003e\n\u003cli\u003eKeep power wiring separated from high-level communication and low-level signal wiring where the installation permits.\u003c\/li\u003e\n\u003cli\u003eRoute field conductors securely and prevent mechanical stress at terminal or connector interfaces.\u003c\/li\u003e\n\u003cli\u003eUse appropriate protective measures for external wiring, including overcurrent protection where required by the system design.\u003c\/li\u003e\n\u003cli\u003eMaintain proper protective and functional grounding according to the system installation standard.\u003c\/li\u003e\n\u003cli\u003eInspect connector seating and module alignment before energizing the chassis.\u003c\/li\u003e\n\u003cli\u003eVerify field polarity and load requirements before applying power.\u003c\/li\u003e\n\u003cli\u003eConfirm the installed hardware configuration and system compatibility before placing the module into service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44547559063640,"sku":"T8513","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ICS-Triplex-T8513-3_1200x1200_16c381fa-33f4-4b16-b0de-f8ee9e88ff40.jpg?v=1786350450","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ics-triplex-t8513-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}