{"product_id":"ics-triplex-t8314-trusted-fibre-tx-rx-unit","title":"ICS Triplex T8314 Trusted Fibre TX\/RX Unit","description":"\u003ch2\u003eICS Triplex T8314 Trusted Fibre TX\/RX Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured to extend the Trusted Expander Bus through a single-mode fibre-optic link, the \u003cstrong\u003eICS Triplex T8314\u003c\/strong\u003e (\u003cstrong\u003eT8314 Trusted Fibre TX\/RX Unit\u003c\/strong\u003e) converts differential copper Expander Bus signals to optical signals and restores them at the remote end. The unit supports a communication distance of up to 10 km and operates as an independent transmitter\/receiver interface within the Trusted remote Expander architecture. (manualzz.com)\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8314\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTrusted Fibre TX\/RX Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eTrusted Expander Bus fibre-optic interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Medium\u003c\/td\u003e\n\u003ctd\u003eSingle-mode fibre optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Communication Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 10 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e250 Mb\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Connector\u003c\/td\u003e\n\u003ctd\u003eSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFibre Configuration\u003c\/td\u003e\n\u003ctd\u003eSeparate Tx and Rx fibres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eDual 24 VDC, diode ORed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e1.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power\u003c\/td\u003e\n\u003ctd\u003e-15 dBm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd\u003e-28 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Propagation Time Difference\u003c\/td\u003e\n\u003ctd\u003e80 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Fibre Length Difference\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eTS32 or TS35 DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e84 x 110 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Weight\u003c\/td\u003e\n\u003ctd\u003e320 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Shipping Size\u003c\/td\u003e\n\u003ctd\u003e14.5 x 30 x 4.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Shipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe T8314 accepts dual 24 VDC feeds through diode ORing. Internally, the Expander Bus signal passes through isolation, filtering, and termination before optical conversion. The remote T8314 reverses this process and returns the signal to the copper Expander Bus. (manualzz.com)\u003c\/p\u003e\n\u003ch3\u003eTMR Safety Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe Trusted architecture uses three independent T8314 communication paths to provide a non-interfering fibre communication arrangement. Each unit operates independently and requires no configuration before installation. Therefore, maintenance personnel can replace an individual unit without interrupting the complete Trusted system operation, subject to the system configuration and maintenance procedure. (manualzz.com)\u003c\/p\u003e\n\u003cp\u003eThe optical interface operates at 250 Mb\/s. For redundant fibre paths, the propagation-time difference must remain within 80 ns, corresponding to a maximum fibre length difference of 15 m. For routes exceeding 2 km, the cable route should be surveyed to verify propagation-time and system timing requirements. (manualzz.com)\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply does the T8314 require?\u003cbr\u003eA: The T8314 accepts 18 VDC to 32 VDC and provides two 24 VDC input paths with diode ORing. Maximum power consumption is 1.7 W. (manualzz.com)\u003c\/p\u003e\n\u003cp\u003eQ: What fibre interface does the T8314 use?\u003cbr\u003eA: The unit uses single-mode fibre with SC connectors and separate Tx and Rx fibres. The specified communication distance reaches up to 10 km. (manualzz.com)\u003c\/p\u003e\n\u003cp\u003eQ: What installation constraint applies to redundant fibre paths?\u003cbr\u003eA: The maximum propagation-time difference is 80 ns, corresponding to a maximum fibre length difference of 15 m. Routes exceeding 2 km require propagation-time verification. (manualzz.com)\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the T8314 on a TS32 or TS35 DIN rail in either horizontal or vertical orientation.\u003c\/li\u003e\n\u003cli\u003eProvide sufficient clearance around the unit for fibre routing and connector access.\u003c\/li\u003e\n\u003cli\u003eThe installation manual specifies a minimum 200 mm clearance on either side for the fibre cable bend radius. (manualzz.com)\u003c\/li\u003e\n\u003cli\u003eConnect the two 24 VDC supply inputs according to the specified polarity and terminal assignment.\u003c\/li\u003e\n\u003cli\u003eUse separate Tx and Rx single-mode fibre connections with compatible SC connectors.\u003c\/li\u003e\n\u003cli\u003eKeep fibre routing within the permitted bend radius specified by the selected cable manufacturer.\u003c\/li\u003e\n\u003cli\u003eFor links longer than 2 km, verify the physical route and propagation-time difference between redundant fibre paths.\u003c\/li\u003e\n\u003cli\u003eDo not connect or disconnect the equipment while energized unless the installation area meets the applicable safety requirements.\u003c\/li\u003e\n\u003cli\u003eObserve ESD precautions when handling the unit or exposed connectors.\u003c\/li\u003e\n\u003cli\u003eVerify communication through the Trusted Expander Interface and Processor diagnostics after installation. (manualzz.com)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44547366912088,"sku":"T8314","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/T8314-3_1200x1200_e90ee550-7f07-4ac4-90ff-4416cb3a3ca3.jpg?v=1786348399","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ics-triplex-t8314-trusted-fibre-tx-rx-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}