{"product_id":"honeywell-tc-ixl061-thermocouple-mv-input-module","title":"Honeywell TC-IXL061 Thermocouple \/ mV Input Module","description":"\u003ch2\u003eHoneywell TC-IXL061 Thermocouple \/ mV Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-IXL061\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-IXL061\u003c\/strong\u003e Thermocouple \/ mV Input Module, operates as a dedicated hardware component for temperature signal acquisition within the Honeywell Experion PKS Chassis I\/O system. The module processes thermocouple and millivolt field inputs through isolated analog channels for controller data acquisition.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple \/ mV Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Chassis I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Inputs\u003c\/td\u003e\n\u003ctd\u003eThermocouple Types J, K, T, E, R, S, B, N; +\/- 100 mV linear inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale (dependent on input range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation\u003c\/td\u003e\n\u003ctd\u003eInternal CJC function, typical accuracy +\/- 0.5 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VDC or 1500 VAC channel-to-system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms to 500 ms configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.5 W to 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg (typical module weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.5 x 14.2 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe TC-IXL061 integrates cold junction compensation (CJC) for thermocouple measurement accuracy and supports isolated analog signal processing between field wiring and the Experion PKS controller interface. Channel-to-channel isolation reduces measurement interference caused by ground potential differences and field signal coupling.\u003c\/p\u003e\n\u003cp\u003eThe module accepts low-level millivolt signals and thermocouple inputs through high impedance analog circuits. Proper shield termination and field cable routing are required to maintain signal integrity in electrically noisy environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What input signals can the TC-IXL061 process?\u003cbr\u003eA: The module supports thermocouple inputs including Types J, K, T, E, R, S, B, and N, as well as +\/- 100 mV linear voltage inputs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TC-IXL061 provide electrical isolation for field signals?\u003cbr\u003eA: Yes. The module provides isolated analog input channels to separate field measurement circuits from the controller system interface.\u003c\/p\u003e\n\u003cp\u003eQ: Is the TC-IXL061 compatible with Honeywell Experion PKS systems?\u003cbr\u003eA: Yes. The module is designed for Honeywell Experion PKS Chassis I\/O configurations and is configured through the corresponding control engineering tools.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated Honeywell Chassis I\/O slot according to the system hardware configuration.\u003c\/li\u003e\n\u003cli\u003eVerify thermocouple polarity before connecting field wiring to prevent incorrect temperature measurement.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cable for low-level mV and thermocouple signals where required by the installation environment.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding practice to minimize electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eSeparate thermocouple and mV signal wiring from high-current power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm field sensor type configuration matches the connected thermocouple specification before commissioning.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections for proper mechanical tightening and secure module seating in the chassis.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44345705201752,"sku":"TC-IXL061","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-IXL061.jpg?v=1783500974","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-tc-ixl061-thermocouple-mv-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}