{"product_id":"honeywell-tc-iah161-high-level-analog-input-module","title":"Honeywell TC-IAH161 High Level Analog Input Module","description":"\u003ch2\u003eHoneywell TC-IAH161 High Level Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-IAH161\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-IAH161\u003c\/strong\u003e High Level Analog Input Module, operates as a dedicated hardware component for analog signal acquisition within Honeywell Experion PKS control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IAH161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 x 14.2 x 14.5 cm (estimated shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0-5 V, 0-10 V, +\/-5 V, +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog voltage and current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Publish Rate\u003c\/td\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop and Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TC-IAH161 is designed for high-level analog signal processing in process control applications. The module accepts standard voltage and current input signals, including 4-20 mA transmitter loops and 0-10 V analog outputs.\u003c\/p\u003e\n\u003cp\u003eThe module architecture supports direct interfacing with field instruments through analog input channels. Channel-to-channel isolation practices should be considered during field wiring to reduce signal interference between independent measurement circuits.\u003c\/p\u003e\n\u003cp\u003eFor current loop applications, the module can process 4-20 mA signals commonly used with industrial transmitters and control instrumentation. Proper shield termination and separation from high-voltage conductors are required to maintain analog signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of analog signals can the TC-IAH161 process?\u003cbr\u003eA: The TC-IAH161 processes voltage inputs of 0-5 V, 0-10 V, +\/-5 V, and +\/-10 V, as well as current inputs of 0-20 mA and 4-20 mA.\u003c\/p\u003e\n\u003cp\u003eQ: How many input channels are available on the TC-IAH161?\u003cbr\u003eA: The module provides 16 single-ended analog input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply is required for the module?\u003cbr\u003eA: The module operates from a 24 VDC power supply with a typical tolerance of +\/-10%.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated Honeywell control system I\/O rack position according to the applicable system hardware configuration.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring polarity matches the configured analog input type before applying power.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cable for low-level analog signals where required by the installation environment.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding practice to minimize electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-current power conductors and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal connections, module addressing, and controller configuration before commissioning.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified input voltage or current ranges during field operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44345701531736,"sku":"TC-IAH161","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-IAH161-3.jpg?v=1783500826","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-tc-iah161-high-level-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}