{"product_id":"honeywell-tc-batt01-lithium-plc-backup-battery","title":"Honeywell TC-BATT01 Lithium PLC Backup Battery","description":"\u003ch2\u003eHoneywell TC-BATT01 Lithium PLC Backup Battery\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-BATT01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-BATT01\u003c\/strong\u003e Lithium PLC Backup Battery, provides memory retention power for Honeywell controller assemblies during primary power interruption conditions. The module supplies a 3.0 VDC lithium backup source for preserving stored controller data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-BATT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLithium PLC Backup Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd\u003eNon-rechargeable Lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e3.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Capacity\u003c\/td\u003e\n\u003ctd\u003e1700 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003ePolarized application-specific connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.068 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34 mm (H) x 17 mm (W) x 17 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandby backup application, battery powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Life\u003c\/td\u003e\n\u003ctd\u003eUp to 10 years at 20 deg C ambient conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eController chassis or processor module mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Process Control Memory Backup Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe TC-BATT01 is designed for controller memory retention functions within Honeywell industrial control platforms. The lithium cell provides a stable backup voltage source for maintaining stored application programs, configuration parameters, and processor memory data when the primary controller power supply is unavailable.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell controller environments, backup battery operation is separated from normal control power circuits. The module does not provide field I\/O power or process signal excitation. Instead, it supports internal memory preservation circuits associated with processor hardware.\u003c\/p\u003e\n\u003cp\u003eMoreover, Honeywell controller architectures may include analog and digital I\/O interfaces using technologies such as 4-20 mA HART loop protocol, FOUNDATION Fieldbus, or Profibus PA connectivity. The TC-BATT01 functions independently from these communication interfaces and only maintains controller memory backup requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the Honeywell TC-BATT01 a rechargeable battery module?\u003c\/strong\u003e\u003cbr\u003eA: No. The TC-BATT01 uses a non-rechargeable lithium cell design and requires replacement after battery service life expiration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What electrical function does the TC-BATT01 provide inside a controller assembly?\u003c\/strong\u003e\u003cbr\u003eA: The module provides a 3.0 VDC backup supply for maintaining processor memory contents during loss of the primary power source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TC-BATT01 supply power to external I\/O devices?\u003c\/strong\u003e\u003cbr\u003eA: No. The battery module is intended for internal memory retention circuits and does not provide operating power for external field devices or I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify controller compatibility and battery model identification before installation.\u003c\/li\u003e\n\u003cli\u003eDisconnect the controller power source according to the applicable maintenance procedure before replacing the battery.\u003c\/li\u003e\n\u003cli\u003eConfirm correct polarity alignment between the battery connector and controller interface.\u003c\/li\u003e\n\u003cli\u003eRoute the battery connection away from high-current power wiring and strong electromagnetic interference sources.\u003c\/li\u003e\n\u003cli\u003eInspect connector contacts for contamination or mechanical damage before installation.\u003c\/li\u003e\n\u003cli\u003eFollow local regulations for disposal of lithium battery components after replacement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44349990404184,"sku":"TC-BATT01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TC-BATT01-3.jpg?v=1783585886","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-tc-batt01-lithium-plc-backup-battery","provider":"IndustriaX Limited","version":"1.0","type":"link"}