{"product_id":"honeywell-mu-tamr02-field-termination-assembly","title":"Honeywell MU-TAMR02 Field Termination Assembly","description":"\u003ch2\u003eHoneywell MU-TAMR02 Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for redundant high-level analog signal termination in Honeywell TDC 3000 and Process Manager systems, the \u003cstrong\u003eHoneywell MU-TAMR02-51304477-100\u003c\/strong\u003e (\u003cstrong\u003eMU-TAMR02\u003c\/strong\u003e Field Termination Assembly) provides direct physical signal routing between field wiring and HLAI processor cards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive field termination assembly, no direct power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304477-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRedundant High-Level Analog Input Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000, Process Manager (PM), Advanced Process Manager (APM), High-Performance Process Manager (HPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC and 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell FTA mounting channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Connection\u003c\/td\u003e\n\u003ctd\u003eHoneywell multi-conductor FTA interface cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Analog Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MU-TAMR02 provides termination and routing functions for Honeywell high-level analog input channels. It receives standard process field signals and transfers them to HLAI processor interfaces through dedicated FTA cabling.\u003c\/p\u003e\n\u003cp\u003eThe assembly supports 4-20 mA HART loop protocol compatibility when used with compatible Honeywell analog input processing hardware. In addition, the termination structure maintains channel separation and supports channel-to-channel isolation requirements defined by the connected I\/O architecture.\u003c\/p\u003e\n\u003cp\u003eThe redundant analog input configuration allows two processing paths to monitor field signals. Therefore, the system can maintain signal availability during a single hardware path interruption when installed within a supported redundant configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MU-TAMR02 provide signal conversion or only signal termination?\u003c\/strong\u003e\u003cbr\u003eA: The MU-TAMR02 performs field wiring termination and signal routing. The connected HLAI processor module performs signal measurement, conversion, and control system processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the MU-TAMR02 operate as a standalone powered module?\u003c\/strong\u003e\u003cbr\u003eA: No. The assembly functions as a passive interface component and does not contain an independent power supply or processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MU-TAMR02 support redundant analog input operation?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The MR designation indicates compatibility with redundant analog input configurations when connected to supported Honeywell process control hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MU-TAMR02 on the designated Honeywell FTA mounting channel according to system hardware documentation.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cable for analog field wiring where required by the process environment.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding standard to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eVerify terminal assignments before applying field signals to prevent incorrect channel routing.\u003c\/li\u003e\n\u003cli\u003eConfirm FTA cable connections between the termination assembly and HLAI processor interface before system startup.\u003c\/li\u003e\n\u003cli\u003eInspect screw terminal tightness during commissioning and scheduled maintenance activities.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44497791942744,"sku":"MU-TAMR02 51304477-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MU-TAMR02-51304477-100-3_1200x1200_c99a30fd-5262-40a4-8ff6-e4072a583886.jpg?v=1785828974","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-mu-tamr02-field-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}