{"product_id":"honeywell-mu-taih02-high-level-analog-input-processor","title":"Honeywell MU-TAIH02 High Level Analog Input Processor","description":"\u003cp\u003eThe Honeywell MU-TAIH02 is a robust high-level analog input processor engineered for precise signal acquisition within industrial process control environments. This module is designed to interface with a variety of field transmitters, including 2-wire and self-powered devices, providing reliable data conversion for complex automation tasks in power generation, chemical processing, and refinery operations.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 differential analog input channels for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003e16-bit A\/D conversion architecture ensuring high measurement resolution and stability.\u003c\/li\u003e\n\u003cli\u003eComprehensive support for standard process signals, including 0-5V, 1-5V, 0.4-2V, and 4-20mA.\u003c\/li\u003e\n\u003cli\u003eIntegrated signal conditioning with single-pole RC filtering to mitigate normal mode interference.\u003c\/li\u003e\n\u003cli\u003eHigh common mode rejection (70 dB) to maintain signal integrity in electrically noisy environments.\u003c\/li\u003e\n\u003cli\u003eIntegrated protection circuitry capable of withstanding differential input voltages up to +\/- 30V.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MU-TAIH02 is specifically suited for Distributed Control Systems (DCS) requiring continuous, high-accuracy monitoring. It is commonly deployed in turbine control, industrial instrumentation, and large-scale process automation where signal stability and noise immunity are critical to preventing system downtime.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-5V, 1-5V, 0.4-2V, 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e4 samples\/second per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit (14-bit utilized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e70 dB (DC to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e32 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (23.5 degC)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.075% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is fully disconnected before installing or removing the module from the chassis.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) mitigation techniques to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ground connections for the chassis to ensure effective common mode noise suppression.\u003c\/li\u003e\n\u003cli\u003eCheck that input signal wiring does not exceed the +\/- 30V maximum input voltage threshold to avoid hardware failure.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is firmly seated in the rack to maintain secure electrical contact with the backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the MU-TAIH02?\u003c\/strong\u003e\u003cbr\u003eIt serves as an analog input processor that converts voltage and current signals from field transmitters into a format suitable for digital processing within a Honeywell DCS.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support 4-20 mA signals?\u003c\/strong\u003e\u003cbr\u003eYes, the module supports 4-20 mA input signals using an integrated 250 Ohm resistance conversion.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the sampling rate of this unit?\u003c\/strong\u003e\u003cbr\u003eThe module performs a full scan of all 16 channels within a 250 ms window, resulting in a rate of 4 samples per second for each individual channel.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44744422490200,"sku":"MU-TAIH02","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_13a42c45-8969-4821-95a4-dea486af74db.jpg?v=1788922662","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-mu-taih02-high-level-analog-input-processor","provider":"IndustriaX Limited","version":"1.0","type":"link"}