{"product_id":"honeywell-mu-ntap02-universal-control-network-2-drop-tap-assembly-kit","title":"Honeywell MU-NTAP02 Universal Control Network 2-Drop Tap Assembly Kit","description":"\u003ch2\u003eHoneywell MU-NTAP02 Universal Control Network 2-Drop Tap Assembly Kit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-NTAP02 (51201394-100)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-NTAP02\u003c\/strong\u003e Universal Control Network 2-Drop Tap Assembly Kit, operates as a passive network hardware component for UCN coaxial trunk connection and field drop-point distribution within Honeywell TDC 3000 and Experion PKS systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-NTAP02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 2.0 kg to 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0 W (passive network component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51201394-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network 2-Drop Tap Assembly Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eHoneywell Universal Control Network (UCN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Interface\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial trunk cable connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003eDual drop tap assembly, one trunk input and one trunk output per tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Impedance\u003c\/td\u003e\n\u003ctd\u003e75 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Method\u003c\/td\u003e\n\u003ctd\u003eMetal mounting bracket with chassis grounding provision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Components\u003c\/td\u003e\n\u003ctd\u003eTwo 2-port drop taps, mounting brackets, associated hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUCN Network Tap Signal Distribution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell MU-NTAP02 provides a passive electrical connection point between UCN trunk cables and connected control network devices. It maintains the 75 Ohm coaxial impedance required by Honeywell UCN communication architecture.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the assembly supports redundant UCN trunk arrangements by providing paired tap hardware for Trunk A and Trunk B network paths. The passive design introduces no power load and preserves continuous network signal transmission through the coaxial backbone.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell process control systems, the module operates independently from analog instrument interfaces such as 4-20 mA HART loops, FOUNDATION Fieldbus, or Profibus PA segments. Instead, it performs physical-layer UCN cable distribution and grounding functions.\u003c\/p\u003e\n\u003cp\u003eThe assembly design incorporates grounding provisions to reduce electromagnetic interference effects. Therefore, correct shield termination and chassis bonding remain required during field installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the Honeywell MU-NTAP02 require an external power supply?\u003cbr\u003eA: No. The MU-NTAP02 is a passive coaxial network tap assembly and does not consume electrical power during operation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MU-NTAP02 support redundant UCN network configurations?\u003cbr\u003eA: Yes. The kit contains two drop tap assemblies that can be applied to redundant UCN trunk structures using separate network paths.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MU-NTAP02 provide signal conversion between different communication protocols?\u003cbr\u003eA: No. The module performs physical UCN coaxial connection and distribution only. It does not convert communication protocols or modify network data.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MU-NTAP02 on a mechanically secured surface using the supplied mounting hardware.\u003c\/li\u003e\n\u003cli\u003eConnect UCN coaxial cables according to the Honeywell UCN wiring design and maintain the specified 75 Ohm cable impedance.\u003c\/li\u003e\n\u003cli\u003eVerify that coaxial connectors remain properly seated to prevent signal reflection and intermittent communication faults.\u003c\/li\u003e\n\u003cli\u003eBond the mounting bracket to the approved chassis ground point to maintain shielding performance.\u003c\/li\u003e\n\u003cli\u003eSeparate UCN coaxial routing from high-voltage power cables and strong electromagnetic interference sources.\u003c\/li\u003e\n\u003cli\u003eConfirm trunk continuity and termination status before placing the UCN network segment into service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44402766315608,"sku":"MU-NTAP02 51201394-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MU-NTAP0251201394-100.jpg?v=1784530911","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-mu-ntap02-universal-control-network-2-drop-tap-assembly-kit","provider":"IndustriaX Limited","version":"1.0","type":"link"}