{"product_id":"honeywell-mc-pc1x02-differential-pressure-transducer","title":"Honeywell MC-PC1X02 Differential Pressure Transducer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe Honeywell MC-PC1X02 is a high-precision differential pressure transducer designed for demanding industrial process control environments. This device provides reliable, continuous measurement of differential pressure, outputting a standard 4-20 mA signal suitable for seamless integration with PLC, DCS, and SCADA control architectures. Engineered for durability, the unit is constructed with a robust polyphenylene sulfide (PPS) housing, ensuring resistance to environmental stressors in applications such as boiler pressure monitoring, gas compression, and water treatment facility automation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBidirectional pressure sensing capability up to +\/- 125 psi.\u003c\/li\u003e\n\u003cli\u003eStandard 4-20 mA analog output for robust, noise-immune signal transmission.\u003c\/li\u003e\n\u003cli\u003eHigh measurement accuracy of +\/- 0.05 percent full scale.\u003c\/li\u003e\n\u003cli\u003eExcellent long-term stability with a drift rate of only +\/- 0.1 percent full scale per year.\u003c\/li\u003e\n\u003cli\u003eIP66-rated enclosure for protection against ingress of dust and moisture.\u003c\/li\u003e\n\u003cli\u003eCompact design with standard NPT threading for straightforward field integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MC-PC1X02 is widely utilized in industrial automation to maintain operational safety and efficiency. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRefinery process skids and gas compression stations.\u003c\/li\u003e\n\u003cli\u003eBoiler and steam pressure management systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial HVAC and environmental control processes.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment plant instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PC1X02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 125 psi (+\/- 8.62 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e12 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e1\/2 inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e1\/4 inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power supply is disconnected before wiring or servicing the transducer.\u003c\/li\u003e\n\u003cli\u003eVerify that the process pressure does not exceed the specified maximum range to avoid sensor damage.\u003c\/li\u003e\n\u003cli\u003eUse appropriate thread sealant on 1\/4 inch NPT process ports to prevent leaks in high-pressure lines.\u003c\/li\u003e\n\u003cli\u003eEnsure electrical conduits are properly sealed at the 1\/2 inch NPT entry to maintain the IP66 ingress protection rating.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling away from high-voltage lines and sources of electromagnetic interference to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eMount the device in a location with minimal vibration to ensure long-term measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary output signal of the MC-PC1X02?\u003c\/strong\u003e\u003cbr\u003eThe device provides a standard 4-20 mA analog current loop signal.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this transducer suitable for outdoor use?\u003c\/strong\u003e\u003cbr\u003eYes, the unit features an IP66 enclosure rating, making it suitable for environments where protection against moisture and dust is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the typical maintenance requirement for this sensor?\u003c\/strong\u003e\u003cbr\u003eDue to its high long-term stability of +\/- 0.1% per year, the sensor requires minimal recalibration, helping to reduce maintenance downtime in critical processes.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44701567156312,"sku":"MC-PC1X02","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_d436da14-9123-4c84-8552-52c93ebe1024.jpg?v=1788382536","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-mc-pc1x02-differential-pressure-transducer","provider":"IndustriaX Limited","version":"1.0","type":"link"}