{"product_id":"honeywell-mc-mu-mc-taox12-analog-output-redundancy-board","title":"Honeywell MC-MU \/ MC-TAOX12 Analog Output Redundancy Board","description":"\u003ch2\u003eHoneywell MC-MU \/ MC-TAOX12 Analog Output Redundancy Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for redundant analog output signal execution in Honeywell TDC 3000 and Experion PKS systems, the \u003cstrong\u003eHoneywell MC-MU \/ MC-TAOX12 (51304335-125)\u003c\/strong\u003e (\u003cstrong\u003eMC-TAOX12\u003c\/strong\u003e Analog Output Redundancy Board) provides direct physical and electrical control path management for 4-20 mA field loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-MU \/ MC-TAOX12 (51304335-125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Redundancy Board \/ Field Termination Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Experion PKS control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output, 4-20 mA and 1-5 VDC signal interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e12 analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-path analog output redundancy support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eHoneywell FTA mounting rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Function\u003c\/td\u003e\n\u003ctd\u003eField signal termination and redundant output routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eApplied for protection against industrial environmental contamination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied through associated Honeywell system interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop Interface and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAOX12 manages analog output transmission between Honeywell control processors and field actuators. Moreover, the board supports signal routing for standard process control loops, including current-based 4-20 mA outputs used by control valves and positioning devices.\u003c\/p\u003e\n\u003cp\u003eHoneywell DCS output assemblies typically maintain channel-to-channel isolation practices to reduce electrical interference between independent field circuits. Therefore, installation requires correct field wiring separation and shield termination according to the control system engineering specification.\u003c\/p\u003e\n\u003cp\u003eThe module supports redundant output architectures where two control paths monitor and maintain analog output availability. The redundancy mechanism allows the active path to transfer control authority when the primary output path becomes unavailable.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the MC-TAOX12 support redundant analog output operation?\u003cbr\u003eA: Yes. The MC-TAOX12 is designed as an analog output redundancy board that manages dual-path output configurations within compatible Honeywell control systems.\u003c\/p\u003e\n\u003cp\u003eQ: What field signals can connect to this module?\u003cbr\u003eA: The module interfaces with analog output signals, including standard 4-20 mA and 1-5 VDC process control loops.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module require special field grounding practices?\u003cbr\u003eA: Field installation should follow Honeywell grounding procedures. Shield layers should terminate according to the system cabinet wiring design, and signal cables should avoid parallel routing with high-voltage power conductors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MC-TAOX12 on the specified Honeywell FTA mounting structure and verify mechanical seating before wiring.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal assignments with the applicable Honeywell system documentation before connecting field devices.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cables for analog output circuits and maintain proper shield grounding practices.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from AC power cables, motor circuits, and high-current switching conductors.\u003c\/li\u003e\n\u003cli\u003eVerify redundant channel wiring before system commissioning to prevent incorrect output path selection.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections for secure mechanical fastening and correct polarity before applying system power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44375610523736,"sku":"MC-MU\/MC-TAOX12 51304335-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MC-MUMC-TAOX1251304335-125-2.jpg?v=1784011769","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-mc-mu-mc-taox12-analog-output-redundancy-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}