{"product_id":"honeywell-fc-tsfire-1624-termination-assembly-module","title":"Honeywell FC-TSFIRE-1624 Termination Assembly Module","description":"\u003ch2\u003eHoneywell FC-TSFIRE-1624 Termination Assembly Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for safe fire detector input termination in Honeywell Safety Manager platforms, the \u003cstrong\u003eHoneywell FC-TSFIRE-1624\u003c\/strong\u003e (\u003cstrong\u003eTSFIRE-1624\u003c\/strong\u003e Termination Assembly Module) provides direct physical and electrical execution for 24 V DC fire detection circuits with line monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSFIRE-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003eTSFIRE-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTermination Assembly Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17 x 7 x 5.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e11 mA typical at 24 V DC external supply, no load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC +25% \/ -15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e570 mA at 24 V DC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Current with EOL Resistors\u003c\/td\u003e\n\u003ctd\u003e70 mA at 24 V DC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Resistance\u003c\/td\u003e\n\u003ctd\u003e680 ohm +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShorted Current\u003c\/td\u003e\n\u003ctd\u003e35 mA at 24 V DC external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Voltage\u003c\/td\u003e\n\u003ctd\u003e17 - 39 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Current\u003c\/td\u003e\n\u003ctd\u003e8.5 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Function\u003c\/td\u003e\n\u003ctd\u003eSafe fire detector input FTA with line monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Function\u003c\/td\u003e\n\u003ctd\u003eFire detection input and global reset of connected sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe FC-TSFIRE-1624 termination assembly module processes 16 fire detector input channels through monitored field wiring circuits. It uses end-of-line resistors to supervise field loop conditions and detect circuit status changes.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell safety system integration, the module maintains channel-to-channel signal separation for discrete fire detection inputs. Therefore, each input channel can provide individual monitoring of connected field devices while maintaining defined electrical characteristics.\u003c\/p\u003e\n\u003cp\u003eThe module supports 24 V DC field circuits and provides line monitoring functions for open-circuit and short-circuit detection. The input design allows connection of fire detection sensors requiring global reset control through the termination assembly interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many fire detector input channels does the FC-TSFIRE-1624 support?\u003cbr\u003eA: The FC-TSFIRE-1624 supports 16 fire detector input channels with line monitoring capability.\u003c\/p\u003e\n\u003cp\u003eQ: What external supply voltage does the FC-TSFIRE-1624 require?\u003cbr\u003eA: The module operates with a 24 V DC external supply within the specified range of +25% and -15%.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide end-of-line supervision?\u003cbr\u003eA: Yes. The FC-TSFIRE-1624 supports end-of-line resistor monitoring for supervised fire detection input circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the termination assembly module inside the designated Honeywell safety system cabinet or approved enclosure.\u003c\/li\u003e\n\u003cli\u003eConnect field fire detector wiring according to the channel assignment and termination requirements defined by the system engineering documentation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper separation between fire detection signal wiring and high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding design and avoid multiple uncontrolled grounding points.\u003c\/li\u003e\n\u003cli\u003eVerify end-of-line resistor installation before commissioning the monitored input circuits.\u003c\/li\u003e\n\u003cli\u003eCheck 24 V DC supply polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eConfirm channel status and input response through the safety controller diagnostic interface after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44382269833304,"sku":"FC-TSFIRE-1624","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-TSFIRE-1624-3.jpg?v=1784100508","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-fc-tsfire-1624-termination-assembly-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}