{"product_id":"honeywell-fc-sdo-0824-safe-digital-output-module","title":"Honeywell FC-SDO-0824 Safe Digital Output Module","description":"\u003ch2\u003eHoneywell FC-SDO-0824 Safe Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC digital output execution in Honeywell safety control platforms, the \u003cstrong\u003eHoneywell FC-SDO-0824\u003c\/strong\u003e (\u003cstrong\u003eSDO-0824 V1.3\u003c\/strong\u003e Safe Digital Output Module) provides direct electrical switching control for safety-related field devices.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-SDO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003eSDO-0824 V1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.5 x 22.5 x 17.5 cm shipping size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eWDG input current: 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e550 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lamp Load\u003c\/td\u003e\n\u003ctd\u003e120 mA (2.9 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.0 VDC at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirement\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (= 4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Isolation and Output Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC-SDO-0824 operates as an output interface module for safety digital switching circuits. Moreover, the module provides 8 output channels with 24 VDC field voltage and supports controlled de-energization functions through secondary means.\u003c\/p\u003e\n\u003cp\u003eThe output stages include suppression diode functionality to manage inductive load switching behavior. In addition, the module limits output interaction through defined crosstalk suppression characteristics between channels.\u003c\/p\u003e\n\u003cp\u003eThe module architecture follows Honeywell safety I\/O design practices with channel-level electrical monitoring. Therefore, field devices receive controlled output states while the controller monitors output conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many digital output channels does the FC-SDO-0824 provide?\u003cbr\u003eA: The FC-SDO-0824 provides 8 digital output channels with a 24 VDC output specification.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current capability of each output module?\u003cbr\u003eA: The module supports a maximum output current of 550 mA and a maximum lamp load of 120 mA (2.9 W).\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support output de-energization functions?\u003cbr\u003eA: Yes. The module supports group de-energization through a secondary means for safety output handling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the FC-SDO-0824 in the specified Honeywell safety controller rack position with correct mechanical alignment and module locking engagement.\u003c\/p\u003e\n\u003cp\u003eVerify field wiring polarity before connecting 24 VDC output circuits. Use appropriate terminal blocks and maintain separation between signal wiring and high-energy conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConnect protective grounding according to the system cabinet design. Ensure cable routing follows Honeywell installation requirements for safety I\/O systems, including proper shielding practices where applicable.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify each output channel operation through the configured safety application logic and confirm field device response under normal and de-energized conditions.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44376244846680,"sku":"FC-SDO-0824","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-SDO-0824-3.jpg?v=1784015726","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-fc-sdo-0824-safe-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}