{"product_id":"honeywell-fc-psuni2424-power-supply-unit","title":"Honeywell FC-PSUNI2424 Power Supply Unit","description":"\u003ch2\u003eHoneywell FC-PSUNI2424 Power Supply Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for 24 VDC power conversion and overvoltage protection execution in industrial control power networks, the \u003cstrong\u003ePhoenix Contact FC-PSUNI2424\u003c\/strong\u003e (\u003cstrong\u003ePSUNI2424\u003c\/strong\u003e Power Supply Unit) provides direct physical and electrical power regulation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-PSUNI2424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e370 x 159 x 67.3 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e600 W output power; input power 712 W at 115 VAC, 691 W typical at 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC \/ 220-240 VAC nominal; operational range 85-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e45-66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e6.2 A at 115 VAC; 3.1 A at 230 VAC at rated DC output load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e25.7 V no load; 25.1 V with 24 A static load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Efficiency\u003c\/td\u003e\n\u003ctd\u003e80% at 100 VAC and 6 A; 84.5% at 100 VAC and 12-24 A; 82% at 230 VAC and 6 A; 87% at 230 VAC and 12-24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;0.99 at 100 VAC and 6-24 A; \u0026gt;0.88 at 230 VAC and 6 A; 0.98 at 230 VAC and 24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60 A; supports 10 A Type C circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Fuse\u003c\/td\u003e\n\u003ctd\u003e10 A fuse for each AC leg line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Protection\u003c\/td\u003e\n\u003ctd\u003e10 A Class CC fuse or 10-13 A Type C MCB according to EN60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standards\u003c\/td\u003e\n\u003ctd\u003eEN61131-2, EN50130-4, EN61000-6-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE; cUL 60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eDC output SELV certified; OVP SIL3 certified according to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C; keep below 40 deg C for long-term storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH non-condensing; derating above 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003ePD2 maximum according to IEC60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e0-2000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Category\u003c\/td\u003e\n\u003ctd\u003eIndustrial installations only; OVC II up to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDIN-Rail Power Conversion and Protection Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-PSUNI2424 integrates regulated DC power conversion with output voltage supervision functions. The unit maintains a 24 VDC supply output while the integrated overvoltage protection circuit limits DC output voltage below 31 V according to IEC 61508 SIL3 requirements.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the power supply includes input EMI filtering with a 2 uF capacitor network between input lines. The design supports industrial AC supply variations from 85 VAC to 265 VAC and maintains controlled inrush current characteristics for circuit breaker coordination.\u003c\/p\u003e\n\u003cp\u003eThe PSUNI2424 uses DIN-rail industrial installation principles and provides surge voltage protection limits suitable for control cabinet power distribution. Therefore, installers must maintain proper grounding, protective earth connection, and separation between AC input wiring and low-voltage DC output circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FC-PSUNI2424 provide SELV classified DC output?\u003cbr\u003eA: Yes. The DC output is SELV certified, and the integrated overvoltage protection maintains output voltage below 31 V according to IEC 61508 SIL3 requirements.\u003c\/p\u003e\n\u003cp\u003eQ: What external circuit protection is specified for the FC-PSUNI2424?\u003cbr\u003eA: The input circuit supports a 10 A Class CC fuse or a 10-13 A Type C MCB according to EN60898-1.\u003c\/p\u003e\n\u003cp\u003eQ: Can the power supply operate in high humidity environments?\u003cbr\u003eA: Yes. The unit supports 5% to 95% RH non-condensing humidity, with output derating required above 40 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the FC-PSUNI2424 inside an industrial control cabinet with adequate ventilation clearance around the enclosure. Connect the protective earth conductor according to applicable electrical installation standards before applying AC input power.\u003c\/p\u003e\n\u003cp\u003eRoute AC input conductors separately from 24 VDC output wiring and sensitive signal cables to reduce electromagnetic interference. Maintain correct polarity on the DC output terminals and verify the output voltage before connecting downstream automation equipment.\u003c\/p\u003e\n\u003cp\u003eUse the specified external fuse or circuit breaker protection device to coordinate input protection. Check cabinet temperature conditions because output capability decreases when operating humidity and ambient temperature exceed specified limits.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44407792795736,"sku":"FC-PSUNI2424","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-PSUNI2424-3.jpg?v=1784624247","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-fc-psuni2424-power-supply-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}