{"product_id":"honeywell-cc-tdil110-digital-input-module","title":"Honeywell CC-TDIL110 Digital Input Module","description":"\u003ch2\u003eHoneywell CC-TDIL110 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TDIL11 PWA51308388-175 REV B2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TDIL11\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete 24 VDC signal acquisition within the Honeywell Experion PKS C300 control system. It transfers field input states from contact devices to the controller for deterministic logic processing and system diagnostics.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies a single hardware revision only. No official suffix decoding or ordering matrix is provided for \u003cstrong\u003ePWA51308388-175 REV B2\u003c\/strong\u003e. Revision compatibility should be verified against the installed Experion PKS hardware and firmware release before replacement.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDIL110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS C300 Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field circuits and system logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequence of Events\u003c\/td\u003e\n\u003ctd\u003eSupported, approximately 1 ms resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal or compression terminal depending on IOTA variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 % to 95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow power dissipation, exact value not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe module is intended for discrete input acquisition in distributed process control applications where field wiring interfaces with the Experion PKS controller through an isolated input stage. Galvanic isolation separates field-side electrical circuits from controller logic to reduce the influence of ground potential differences and externally induced electrical disturbances. Sequence of Events support provides hardware time stamping for chronological event recording during process transitions and fault analysis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support online replacement during controller operation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied documentation does not specify hot-swap capability. Replacement procedures should follow the maintenance instructions defined for the installed Experion PKS system revision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can different field voltage levels be connected to separate input channels?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified nominal operating level is 24 VDC with an input range of 18 VDC to 30 VDC. Field devices should operate within this specified voltage range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is firmware matching required before module replacement?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Hardware revision and system compatibility should be verified against the existing Experion PKS controller and associated I\/O infrastructure before installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate field power before connecting or removing field wiring.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal assignments against the applicable Honeywell wiring documentation before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage signal wiring from high-power conductors to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the site's grounding standard to avoid unwanted ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify field input voltage is within the specified operating range before applying power.\u003c\/li\u003e\n\u003cli\u003eConfirm the installed hardware revision is compatible with the existing controller, I\/O termination assembly, and system firmware.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44306799099992,"sku":"CC-TDI110","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-TDI110-3.jpg?v=1782980143","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-cc-tdil110-digital-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}