{"product_id":"honeywell-cc-pwr401-system-power-supply-module","title":"Honeywell CC-PWR401 System Power Supply Module","description":"\u003ch2\u003eHoneywell CC-PWR401 System Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PWR401\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51454475-100\u003c\/strong\u003e system power supply module, operates as a dedicated hardware component for regulated DC power distribution within the Experion PKS C300 controller and Series 8 I\/O subsystems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PWR401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 8 module width, single slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 % to 95 % RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eRegulated 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 20 A total load capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural convection (fanless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Bus \u0026amp; I\/O Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Series 8 backplane to distribute regulated DC power to the controller processor and I\/O modules. It supports seamless integration into the Experion PKS network architecture, maintaining stable voltage levels during transient load changes. Communication of diagnostic data, including output voltage drop and internal temperature warnings, is transmitted via the backplane to the controller for real-time monitoring. The unit's galvanic isolation prevents ground loop formation between the primary input source and sensitive control electronics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CC-PWR401 be hot-swapped in a redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swap replacement when installed on a compatible redundant power carrier, allowing removal and insertion while the system remains fully powered.\u003c\/p\u003e\n\u003cp\u003eQ: What is the behavior of the LED indicators during a fault condition?\u003c\/p\u003e\n\u003cp\u003eA: The green \"OK\" LED extinguishes, and the red \"Fault\" LED illuminates to indicate an internal failure or loss of input power.\u003c\/p\u003e\n\u003cp\u003eQ: Is external cooling required for operation at 70 deg C ambient temperature?\u003c\/p\u003e\n\u003cp\u003eA: No, the module utilizes a fanless design with natural convection cooling sufficient for its specified operating range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the CC-PWR401 directly onto the designated Honeywell power carrier. Ensure the input power wiring uses appropriately sized conductors terminated with secure lugs. Verify that the input supply is isolated and meets the nominal 24 VDC specification before energizing. Maintain clear airflow paths around the module to preserve passive cooling efficiency. Confirm proper seating of the module into the backplane connector to avoid intermittent power distribution.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44318865391704,"sku":"CC-PWR401","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-PWR401-3.jpg?v=1783063632","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-cc-pwr401-system-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}