{"product_id":"honeywell-900a16-0101-hc900-high-level-analog-input-module","title":"Honeywell 900A16-0101 HC900 High-Level Analog Input Module","description":"\u003ch2\u003eHoneywell 900A16-0101 HC900 High-Level Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-level analog signal acquisition in Honeywell HC900 \/ ControlEdge 900 systems, the \u003cstrong\u003eHoneywell 900A16-0101\u003c\/strong\u003e (\u003cstrong\u003e900A16-0101\u003c\/strong\u003e High-Level Analog Input Module) provides direct physical signal conversion for voltage and current field inputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900A16-0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eHC900 \/ ControlEdge 900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eConfigurable voltage and current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-10 V, +\/- 10 V, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated: +\/- 0.1% of range; Field calibrated: +\/- 0.05% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms parallel module update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 Mohm for voltage input; 250 ohm for current input with shunt resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eUp to 400 VDC channel-to-channel isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Isolation\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 VDC channel-to-backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 75 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 50 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Rejection\u003c\/td\u003e\n\u003ctd\u003eCMRR greater than 90 dB at 120 VAC; SMRR greater than 31 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Shipping Size\u003c\/td\u003e\n\u003ctd\u003e13.3 x 3 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Process Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 900A16-0101 module processes standard process instrumentation signals through configurable analog input channels. Each channel accepts voltage or current inputs independently, which allows mixed signal measurement within the same module.\u003c\/p\u003e\n\u003cp\u003eThe module supports 4-20 mA HART loop protocol applications when used with compatible external transmitters and system configurations. Additionally, the channel-to-channel isolation structure separates field circuits and reduces signal interaction during multi-point analog measurement.\u003c\/p\u003e\n\u003cp\u003eThe integrated 250 ohm current shunt resistor can be enabled through onboard DIP switch settings. Therefore, external precision resistors are not required for standard current loop measurement configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the Honeywell 900A16-0101 support mixed analog input types on one module?\u003cbr\u003eA: Yes. Each of the 16 input channels can be configured independently for voltage or current signal measurement.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide electrical isolation between input channels?\u003cbr\u003eA: Yes. The module provides galvanic isolation between individual channels and between field input circuits and the HC900 backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply interface does the 900A16-0101 use?\u003cbr\u003eA: The module receives backplane power from the HC900 system and requires 5 VDC backplane power with an additional 24 VDC supply connection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 900A16-0101 module in the designated HC900 \/ ControlEdge 900 rack position according to the controller hardware configuration manual.\u003c\/p\u003e\n\u003cp\u003eConnect analog field wiring using shielded instrumentation cable where required. Ground cable shields at the recommended single grounding point to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eSeparate analog signal wiring from high-voltage power cables and switching circuits. Verify polarity, signal range configuration, and channel settings before applying field power.\u003c\/p\u003e\n\u003cp\u003eCheck module LED status indicators after installation. Confirm normal module operation through the controller configuration software before placing the analog channels into process service.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44497876746328,"sku":"900A16-0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900A16-0101-3_1200x1200_4129eb6b-d6fb-436e-8185-10887b7f8bd5.jpg?v=1785831279","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-900a16-0101-hc900-high-level-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}