{"product_id":"honeywell-900a01-0002-controledge-hc900-analog-input-module","title":"Honeywell 900A01-0002 ControlEdge HC900 Analog Input Module","description":"\u003ch2\u003eHoneywell 900A01-0002 ControlEdge HC900 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900A01-0002\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900A01-0002\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for analog signal acquisition within the Honeywell ControlEdge HC900 controller system. The module converts field transmitter signals into digital process values for controller execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900A01-0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell ControlEdge HC900 Controller Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Analog Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog field input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Function\u003c\/td\u003e\n\u003ctd\u003eAnalog signal acquisition and digital value conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eHC900 rack chassis mounting \/ DIN rail installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 in x 5.3 in x 6.0 in (3.8 cm x 13.3 cm x 15.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProcess monitoring, logic control, and analog data acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART and Process Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900A01-0002 interfaces with analog field devices through the ControlEdge HC900 I\/O architecture. The module receives transmitter outputs and transfers processed values through the controller backplane communication path.\u003c\/p\u003e\n\u003cp\u003eThe module supports process instrumentation applications where analog measurement signals require conversion into controller-readable values. Additionally, Honeywell process I\/O designs commonly apply channel-to-channel isolation and signal conditioning methods to reduce interference between field measurement circuits.\u003c\/p\u003e\n\u003cp\u003eThe module operates within the HC900 platform, which supports integration with distributed process instruments using standard industrial signal interfaces. Therefore, correct field wiring, signal shielding, and grounding practices directly affect measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 900A01-0002 be installed outside the Honeywell ControlEdge HC900 platform?\u003cbr\u003eA: No. The module is designed specifically for installation within the Honeywell ControlEdge HC900 controller rack architecture and requires the compatible chassis and backplane interface.\u003c\/p\u003e\n\u003cp\u003eQ: How should analog field wiring be connected to the module?\u003cbr\u003eA: Field wiring should follow industrial instrumentation practices. Use shielded cables for low-level analog signals and connect shields according to the site grounding standard.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot swapping during controller operation?\u003cbr\u003eA: Hot swap capability depends on the HC900 rack configuration and system firmware. Verify the controller hardware manual before removing or inserting the module during operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated HC900 rack position and verify mechanical engagement with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eConfirm that the controller power supply is isolated before performing module installation or removal.\u003c\/li\u003e\n\u003cli\u003eRoute analog signal cables separately from high-voltage power conductors and high-frequency switching sources.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cables for analog inputs where electromagnetic interference may affect signal quality.\u003c\/li\u003e\n\u003cli\u003eVerify terminal assignments before connecting field transmitters or analog sources.\u003c\/li\u003e\n\u003cli\u003eCheck grounding continuity between field devices, cable shields, and the control system grounding point.\u003c\/li\u003e\n\u003cli\u003eConfirm firmware compatibility between the I\/O module and the HC900 controller before system commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44503140106328,"sku":"900A01-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900A01-0002-2_1200x1200_242878ed-764d-4b18-a9a4-ec0782633687.jpg?v=1785920379","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-900a01-0002-controledge-hc900-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}