{"product_id":"honeywell-900a01-0001-controledge-hc900-universal-analog-input-module","title":"Honeywell 900A01-0001 ControlEdge HC900 Universal Analog Input Module","description":"\u003ch2\u003eHoneywell 900A01-0001 ControlEdge HC900 Universal Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for multi-signal analog acquisition in the Honeywell ControlEdge HC900 Control System, the \u003cstrong\u003eHoneywell 900A01-0001\u003c\/strong\u003e (\u003cstrong\u003e900A01-0001\u003c\/strong\u003e Universal Analog Input Module) provides direct electrical conversion of field voltage, current, thermocouple, RTD, and resistance signals into controller data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900A01-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900 Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Thermocouples, RTDs, Resistance, Millivolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC, 1 to 5 VDC, +\/-10 VDC, 0 to 100 mVDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 0-20 mA DC with external shunt resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit binary conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Cycle Update\u003c\/td\u003e\n\u003ctd\u003eUp to 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-chassis galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eTri-color LED module status indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Function\u003c\/td\u003e\n\u003ctd\u003eSupported with RIUP operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eG3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Interface and Isolation Features\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900A01-0001 uses individual channel configuration to process different analog field signals through the ControlEdge HC900 architecture. Each input channel performs signal conversion independently, therefore allowing mixed sensor types within one module.\u003c\/p\u003e\n\u003cp\u003eThe module supports process instrumentation interfaces including 4-20 mA current loops and voltage measurement inputs. In addition, thermocouple channels use temperature compensation functions within the controller configuration environment, while RTD inputs provide direct resistance-based temperature measurement.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the channel-to-channel isolation design reduces signal interference between independent field circuits. This isolation method supports stable analog measurement when multiple transmitters, sensors, or grounding conditions exist within the same control cabinet.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the Honeywell 900A01-0001 support mixed input signal types on one module?\u003cbr\u003eA: Yes. Each of the 8 channels can be individually configured for voltage, current, thermocouple, RTD, resistance, or millivolt input signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 900A01-0001 module be replaced while the ControlEdge HC900 system remains powered?\u003cbr\u003eA: Yes. The module supports RIUP hot-swapping operation, allowing removal and insertion under power according to system installation procedures.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle field signal interference?\u003cbr\u003eA: The module provides channel-to-channel and channel-to-chassis galvanic isolation to reduce ground loop effects and electrical noise coupling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the 900A01-0001 module in the designated ControlEdge HC900 rack position according to the controller hardware configuration.\u003c\/li\u003e\n\u003cli\u003eVerify terminal wiring before applying field power to prevent incorrect signal connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cables for low-level analog signals such as thermocouples, RTDs, and millivolt inputs.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the cabinet grounding design to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-voltage power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm input type configuration in the Process Control Designer software before placing the channel into operation.\u003c\/li\u003e\n\u003cli\u003eDuring hot-swap replacement, follow the approved rack maintenance procedure to prevent unintended controller events.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44467287785560,"sku":"900A01-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900A01-0001-3.jpg?v=1785136604","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-900a01-0001-controledge-hc900-universal-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}