{"product_id":"honeywell-8c-taixb1-analog-input-module","title":"Honeywell 8C-TAIXB1 51307129-175 S8 HLAI IOTA 16-Channel Analog Input Module","description":"\u003cp\u003eThe Honeywell 8C-TAIXB1 (51307129-175) is a high-level analog input (HLAI) IOTA module designed for the Experion LX distributed control system. This 16-channel assembly features conformal coating for enhanced durability in industrial environments and supports both redundant and non-redundant configurations. The module is engineered for efficient process monitoring, providing integrated excitation power to eliminate the need for external marshalling power supplies.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density I\/O:\u003c\/strong\u003e Supports 16 analog input channels for 4-20 mA signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Power Management:\u003c\/strong\u003e Features on-board excitation power, simplifying field wiring and reducing installation complexity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Includes extensive built-in self-diagnostics to ensure system integrity and rapid fault identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides electrical isolation to protect sensitive control circuitry from field-side disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Configuration:\u003c\/strong\u003e Supports internal or external field power selection and optional redundancy for critical control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Coated circuitry provides increased resistance to harsh industrial conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8C-TAIXB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307129-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Rating\u003c\/td\u003e\n\u003ctd\u003e105 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection (60 Hz)\u003c\/td\u003e\n\u003ctd\u003e19 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before installing or removing the IOTA module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is properly seated in the rack assembly and secured using the provided mounting hardware.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog input signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices according to Honeywell Experion installation standards to ensure signal accuracy and safety.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate airflow around the module to keep operating temperatures within the specified 0 to 60 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support redundancy?\u003c\/strong\u003e Yes, the 8C-TAIXB1 supports optional redundancy configurations within the Experion LX architecture.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs external power required for the field instruments?\u003c\/strong\u003e This module provides on-board excitation power, which often removes the requirement for external marshalling power supplies for standard field devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the conformal coating?\u003c\/strong\u003e The coating provides a protective barrier against moisture, dust, and corrosive elements, extending the lifespan of the module in demanding industrial process environments.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44693492629592,"sku":"8C-TAIXB1","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_c164f42c-a406-4d9c-a704-153fb782d2c0.jpg?v=1788286271","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-8c-taixb1-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}