{"product_id":"honeywell-8c-pooda1-series-8-analog-output-module","title":"Honeywell 8C-POODA1 Series 8 Analog Output Module","description":"\u003ch2\u003eHoneywell 8C-POODA1 Series 8 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog current signal execution in Honeywell Experion PKS C300 control systems, the \u003cstrong\u003eHoneywell 8C-POODA1\u003c\/strong\u003e (\u003cstrong\u003e8C-POODA1\u003c\/strong\u003e Analog Output Module) provides direct electrical output conversion for field control loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-POODA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell C300 Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e12 to 16 bits typical DAC resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eHART pass-through compatible depending on base configuration and firmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported through redundant module base configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-bus galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSeries 8 vertical I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eAvailable for harsh environmental applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop and Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-POODA1 processes digital control commands from the Experion PKS C300 controller and converts them into analog 4-20 mA output signals for field actuators. Therefore, the module supports direct regulation of devices such as control valves, positioners, and variable frequency drives.\u003c\/p\u003e\n\u003cp\u003eThe module supports HART pass-through functions when the installed base configuration and firmware provide compatibility. Additionally, channel-to-channel and channel-to-bus galvanic isolation separates field circuits from internal system communication paths, reducing interference between independent analog loops.\u003c\/p\u003e\n\u003cp\u003eThe Series 8 architecture supports high I\/O density within the Experion PKS platform. Furthermore, the module supports removal and insertion under power (RIUP) functions for maintenance activities when installed within compatible Series 8 configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8C-POODA1 support hot-swapping during system operation?\u003cbr\u003eA: The module supports Removal and Insertion Under Power (RIUP) when installed in compatible Honeywell Series 8 I\/O configurations. The site procedure must follow the approved Experion PKS maintenance guidelines.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field signals does the 8C-POODA1 generate?\u003cbr\u003eA: The module provides analog output signals in the 4-20 mA DC range for connection to field control devices.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide electrical isolation between output channels?\u003cbr\u003eA: Yes. The module design provides channel-to-channel and channel-to-bus galvanic isolation for separated analog output circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the 8C-POODA1 module only in compatible Honeywell Series 8 I\/O termination and carrier assemblies.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring polarity matches the assigned analog output channel terminals before energizing the loop.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cables for analog current loops where electromagnetic interference may affect signal stability.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to site grounding standards and avoid creating multiple grounding paths.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-current power cables and variable frequency drive output cables.\u003c\/li\u003e\n\u003cli\u003eConfirm controller configuration, module addressing, and I\/O channel assignments before commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify output loop operation using calibrated measurement equipment before connecting final field actuators.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44451748511832,"sku":"8C-POODA1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/8C-POODA1-3.jpg?v=1784877396","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-8c-pooda1-series-8-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}