{"product_id":"honeywell-10213-2-3-fail-safe-digital-output-module","title":"Honeywell 10213\/2\/3 Fail-Safe Digital Output Module","description":"\u003ch2\u003eHoneywell 10213\/2\/3 Fail-Safe Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10213\/2\/3\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e10213\/2\/3\u003c\/strong\u003e Fail-Safe Digital Output Module, operates as a dedicated hardware component for fail-safe output switching within Honeywell FSC Safety Instrumented System platforms. The module executes field device control through solid-state digital output channels with defined safe-state behavior.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10213\/2\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e12200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFail-Safe Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication System\u003c\/td\u003e\n\u003ctd\u003eHoneywell Fail-Safe Controller (FSC) \/ Safety Instrumented System (SIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 solid-state digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eFail-safe solid-state switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Output Voltage\u003c\/td\u003e\n\u003ctd\u003e48 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Channel Current\u003c\/td\u003e\n\u003ctd\u003e750 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Channel Load\u003c\/td\u003e\n\u003ctd\u003e36 W per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 25 mA at 5 VDC; approx. 20 mA at 48 VDC no load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 12.7 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Shipping Size\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 12.7 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFail-Safe Output Execution and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 10213\/2\/3 module controls field actuators through isolated solid-state output circuits. It monitors output conditions and drives connected devices to the configured safe state when internal diagnostics detect abnormal operation.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module applies galvanic isolation between controller electronics and field wiring interfaces. This isolation reduces electrical interference effects and supports fail-safe state execution in SIS architectures.\u003c\/p\u003e\n\u003cp\u003eThe output circuitry includes protection functions for inductive and resistive loads. Therefore, field devices such as solenoid valves, relays, alarms, and shutdown actuators can receive controlled switching signals from the FSC platform.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the Honeywell 10213\/2\/3 support hot-swap replacement?\u003cbr\u003eA: The module design supports maintenance replacement procedures within FSC rack configurations when the system configuration permits. Operators must follow approved shutdown and replacement procedures.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output faults?\u003cbr\u003eA: The module uses diagnostic monitoring and fail-safe output logic to force outputs into predefined safety states when detected faults occur.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field devices can connect to this digital output module?\u003cbr\u003eA: The module supports field devices requiring solid-state digital switching, including actuators, solenoids, relays, and alarm devices within supported electrical limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated Honeywell FSC rack slot according to system configuration documentation.\u003c\/li\u003e\n\u003cli\u003eVerify rack power isolation before module insertion or removal.\u003c\/li\u003e\n\u003cli\u003eUse properly terminated field wiring and maintain separation between signal cables and high-energy power conductors.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to plant grounding standards to reduce electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eConfirm output polarity, field voltage level, and load characteristics before energizing connected devices.\u003c\/li\u003e\n\u003cli\u003ePerform system diagnostics after installation to verify correct channel operation and fail-safe response behavior.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44497842274392,"sku":"10213\/2\/3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/10213-2-3-3_1200x1200_53c0db37-d762-4ea2-b544-bc093e9c972f.jpg?v=1785830041","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-10213-2-3-fail-safe-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}