{"product_id":"honeywell-10206-2-1-digital-output-module","title":"Honeywell 10206\/2\/1 Digital Output Module","description":"\u003ch2\u003eHoneywell 10206\/2\/1 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10206\/2\/1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e10206\/2\/1\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for 24 VDC discrete actuator control within Honeywell FSC Safety Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10206\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Family\u003c\/td\u003e\n\u003ctd\u003eHoneywell FSC Safety Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC solid-state source output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e12 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eTwo groups of six channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Channel Current\u003c\/td\u003e\n\u003ctd\u003e550 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Power\u003c\/td\u003e\n\u003ctd\u003e13 W per output channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lamp Load\u003c\/td\u003e\n\u003ctd\u003e275 mA, 6.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protected solid-state output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Load Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated suppression diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 1.5 VDC at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff Current\u003c\/td\u003e\n\u003ctd\u003eLess than 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatchdog Input Current\u003c\/td\u003e\n\u003ctd\u003e0.06 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Consumption\u003c\/td\u003e\n\u003ctd\u003e25 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Current\u003c\/td\u003e\n\u003ctd\u003e230 mA without output load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space Requirement\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TÜV, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Compatibility\u003c\/td\u003e\n\u003ctd\u003eVersion 3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Coding\u003c\/td\u003e\n\u003ctd\u003eHoles A9, C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Coding\u003c\/td\u003e\n\u003ctd\u003eLarge pins A9, C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Output Control\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 10206\/2\/1 provides twelve solid-state digital output channels for discrete field device operation. Each channel switches a 24 VDC supply source and supports resistive and inductive loads. Additionally, the module divides outputs into two six-channel groups, which allows separate external supply connections for field power distribution.\u003c\/p\u003e\n\u003cp\u003eThe output circuitry integrates short-circuit protection and suppression components. Therefore, the module reduces switching disturbances when controlling inductive devices such as solenoid valves and relay coils. The FSC watchdog function monitors system operation and forces output deactivation when the controller enters a shutdown condition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the Honeywell 10206\/2\/1 provide fail-safe tested outputs?\u003cbr\u003eA: No. The module provides standard solid-state digital outputs and does not implement tested fail-safe output functions.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive field loads?\u003cbr\u003eA: The module integrates suppression diodes to reduce voltage disturbances generated by inductive loads during switching operations.\u003c\/p\u003e\n\u003cp\u003eQ: How are the output channels arranged for external power connection?\u003cbr\u003eA: The twelve channels are divided into two groups of six outputs, allowing separate 24 VDC external supply connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the Honeywell 10206\/2\/1 in the designated FSC rack position according to the hardware configuration requirements. Verify module coding positions before insertion to prevent incorrect rack installation.\u003c\/p\u003e\n\u003cp\u003eConnect the external 24 VDC field supply lines according to the specified output group arrangement. Separate field wiring from high-voltage power cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eUse appropriate shield grounding practices for connected field devices when required by the installation design. Confirm actuator polarity, load current, and protection requirements before commissioning.\u003c\/p\u003e\n\u003cp\u003eDuring maintenance activities, verify output status through FSC diagnostics before disconnecting field wiring. Follow the approved FSC system procedures for module replacement and functional testing.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44497853284440,"sku":"10206\/2\/1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/10206-2-1-3_1200x1200_b64c3060-df43-49aa-85fe-2c8345411210.jpg?v=1785830252","url":"https:\/\/www.industriaxplc.com\/ar\/products\/honeywell-10206-2-1-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}