{"product_id":"hart-analog-output-module-cc-taix11-honeywell","title":"HART Analog Output Module | CC-TAIX11 | Honeywell","description":"\u003ch2\u003eHoneywell CC-TAIX11 HART Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal output execution in Honeywell Experion PKS C300 architecture, the \u003cstrong\u003eHoneywell CC-TAIX11\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAIX11\u003c\/strong\u003e HART Analog Output Module, provides direct electrical interface termination for field-side current loop output channels within distributed control I\/O subsystems.\u003c\/p\u003e\n\u003cp\u003eThe module functions as a HART-enabled analog output interface supporting 4-20 mA loop signaling with digital overlay communication. Electrical drive capacity is specified at 0.195 A with 24 VDC nominal supply. Field wiring is routed through a fixed 12 inch rear termination arrangement for cabinet integration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12 inch termination assembly (R-12 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 0.195 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output, HART enabled (4-20 mA loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS \/ C300 I\/O subsystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Loop Electrical Characteristics (HART Analog Output Layer)\u003c\/h3\u003e\n\u003cp\u003eWithin Honeywell Experion C300 architectures, the module participates in 4-20 mA HART loop protocol execution, where analog current output is superimposed with FSK digital communication signals. Channel-level signal integrity depends on loop impedance matching and correct grounding of shielded field cabling. The output stage is designed for controlled current sourcing behavior into standard process instrumentation loads, with HART carrier modulation preserved across the loop without separation of physical wiring layers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TAIX11 support hot-swap replacement in a live I\/O rack?\u003cbr\u003eA: Hot-swap capability depends on C300 chassis configuration. Electrical loop must be placed in safe state or isolated prior to module extraction to prevent current interruption transients.\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane load behavior of the CC-TAIX11?\u003cbr\u003eA: The module draws power from the C300 backplane at 24 VDC nominal input level. Exact backplane current distribution is managed by chassis power segmentation and is not independently configurable at module level.\u003c\/p\u003e\n\u003cp\u003eQ: Is HART communication maintained during analog output operation?\u003cbr\u003eA: Yes. HART digital signal is multiplexed over the same 4-20 mA loop using FSK modulation without requiring additional physical conductors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure loop wiring is isolated from high-voltage switching conductors to minimize induced noise on 4-20 mA current paths\u003c\/li\u003e\n\u003cli\u003eMaintain shield termination at a single grounded point to avoid ground loop formation\u003c\/li\u003e\n\u003cli\u003eVerify loop resistance is within transmitter and field device operational limits prior to energization\u003c\/li\u003e\n\u003cli\u003eInsert module only into compatible Honeywell C300 I\/O termination base with power removed\u003c\/li\u003e\n\u003cli\u003eConfirm polarity alignment for current loop terminals before commissioning\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44306823905368,"sku":"CC-TAIN11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-TAIN11-3.jpg?v=1782982260","url":"https:\/\/www.industriaxplc.com\/ar\/products\/hart-analog-output-module-cc-taix11-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}