{"product_id":"ge-multilin-ursha-ur-sha-power-supply-module","title":"GE Multilin URSHA UR-SHA Power Supply Module","description":"\u003ch2\u003eGE Multilin URSHA UR-SHA Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for regulated DC power conversion in GE Multilin Universal Relays platforms, the \u003cstrong\u003eGE Multilin URSHA\u003c\/strong\u003e (\u003cstrong\u003eUR-SHA\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution for internal relay power distribution and dry contact input energization.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eURSHA \/ UR-SHA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 cm x 16.5 cm x 16.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial relay environment; conformal coating supports harsh operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInternal power supply load dependent on connected UR relay configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relays (UR Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 to 250 VDC \/ 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry Contact Voltage Output\u003c\/td\u003e\n\u003ctd\u003e48 VDC auxiliary output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Interface\u003c\/td\u003e\n\u003ctd\u003ePower health alarm contact and front-panel LED status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Feature\u003c\/td\u003e\n\u003ctd\u003eConformal coating for moisture, contamination, and chemical exposure resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network and Industrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe URSHA module operates within the GE Multilin UR plug-in architecture and provides the internal DC supply rails required by relay processors, communication modules, and I\/O assemblies. The standardized backplane interface supports modular replacement procedures and maintains compatibility with UR series protective relay chassis including B30, C30, L90, T60, and N60 configurations.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility remains dependent on the host UR relay platform and installed hardware revision. The module performs supply health supervision through internal diagnostics and provides alarm indication through relay status contacts and front-panel LED monitoring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the URSHA module be replaced while the relay system remains installed?\u003cbr\u003eA: The URSHA uses the UR series plug-in modular architecture. Replacement procedures must follow the applicable relay maintenance instructions and power isolation requirements before module removal.\u003c\/p\u003e\n\u003cp\u003eQ: What protection method is applied to the electronic assembly?\u003cbr\u003eA: The module uses conformal coating to protect electronic components against moisture, airborne contaminants, chemical corrosion, and environmental stress.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic information is available from the module?\u003cbr\u003eA: The module provides internal supply monitoring, front-panel LED status indication, and power health alarm contact output for relay system supervision.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the URSHA module only in the designated power supply slot of compatible GE Multilin UR series chassis.\u003c\/li\u003e\n\u003cli\u003eVerify auxiliary AC or DC input wiring before energizing the relay assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain proper separation between power wiring, communication wiring, and sensitive signal conductors.\u003c\/li\u003e\n\u003cli\u003eConnect grounding and shielding according to the relay cabinet grounding design and site electrical standards.\u003c\/li\u003e\n\u003cli\u003eInspect the module connector, backplane interface, and mechanical locking mechanism before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm LED status and alarm contact behavior after power application.\u003c\/li\u003e\n\u003cli\u003eAvoid handling the coated circuit surfaces with contaminated tools or materials during maintenance activities.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44494952398936,"sku":"URSHA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/URSHB.jpg?v=1785751135","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-multilin-ursha-ur-sha-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}