{"product_id":"ge-multilin-urghh-ur-ghh-universal-relay-hardware-module","title":"GE Multilin URGHH UR-GHH Universal Relay Hardware Module","description":"\u003ch2\u003eGE Multilin URGHH UR-GHH Universal Relay Hardware Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital protection and control execution in GE Multilin Universal Relay (UR) Series platforms, the \u003cstrong\u003eGE Multilin URGHH\u003c\/strong\u003e (\u003cstrong\u003eURGHH\u003c\/strong\u003e Hardware Module) provides direct physical\/electrical execution within modular protection relay architectures. The module supports configurable CT\/VT acquisition, digital I\/O processing, communication interfaces, and programmable protection logic functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eURGHH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.5 in L x 6.5 in W x 1.75 in H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C (-40 deg F to +140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDepends on configured UR hardware assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-based Digital Protection \u0026amp; Control Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eModular chassis with field-replaceable CPU, power supply, I\/O, and CT\/VT modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Logic Engine\u003c\/td\u003e\n\u003ctd\u003eFlexLogic programmable logic engine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Options\u003c\/td\u003e\n\u003ctd\u003e110-250 VDC \/ 110-230 VAC or 24-48 VDC hardware options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A \/ 5 A secondary rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT Inputs\u003c\/td\u003e\n\u003ctd\u003e60-300 VAC secondary rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003eOptically isolated digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003eForm-A \/ Form-C latching and fast-acting relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus RTU\/TCP, DNP3.0, IEEE 1588 PTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003eRedundant 10\/100Base-T RJ45 or 100Base-FX fiber ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Functions\u003c\/td\u003e\n\u003ctd\u003ePRP and HSR support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Interface\u003c\/td\u003e\n\u003ctd\u003eGraphical display, programmable LEDs, local control keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eIP54 front panel, IP20 rear terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Interface\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL\/cUL, IEEE C37.90, IEC 60255 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Multilin UR Series Communication and Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe URGHH operates as part of the GE Multilin Universal Relay modular hardware environment. The architecture uses replaceable functional modules for processing protection algorithms, measurement acquisition, communication handling, and local control execution.\u003c\/p\u003e\n\u003cp\u003eThe platform supports deterministic network communication through IEC 61850, Modbus, DNP3.0, and IEEE 1588 Precision Time Protocol. Ethernet options include redundant copper and fiber interfaces with PRP\/HSR network redundancy support.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility is managed through the EnerVista UR software environment, allowing supported configuration files and firmware packages to be applied according to the installed UR hardware configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the URGHH module operate as a standalone protection relay?\u003cbr\u003eA: No. The URGHH is a hardware configuration\/module variant within the GE Multilin Universal Relay platform and requires integration with the corresponding UR chassis assembly and configured system modules.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field wiring interfaces are supported?\u003cbr\u003eA: The Universal Relay hardware architecture supports CT\/VT secondary inputs, optically isolated digital inputs, relay output contacts, and communication interfaces through the installed module configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support redundant communication networks?\u003cbr\u003eA: The UR platform supports redundant Ethernet configurations including PRP and HSR functions when compatible communication hardware is installed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module only within the designated GE Multilin Universal Relay chassis position defined by the hardware configuration.\u003c\/li\u003e\n\u003cli\u003eVerify CT and VT secondary wiring polarity before energizing protection circuits.\u003c\/li\u003e\n\u003cli\u003eSeparate communication wiring from high-voltage switching conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables where required by the installation environment and terminate cable shields according to site grounding practices.\u003c\/li\u003e\n\u003cli\u003eConfirm rear terminal connections are mechanically secured before applying auxiliary power.\u003c\/li\u003e\n\u003cli\u003eVerify installed firmware compatibility with the configured UR hardware modules before commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain required enclosure protection levels after panel installation and wiring completion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44497680269400,"sku":"URGHH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ge-ur8lh-multilin-ct-vt-module-hgc4vsapx3v.png?v=1758593015","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-multilin-urghh-ur-ghh-universal-relay-hardware-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}