{"product_id":"ge-multilin-ur6gv-ur-6gv-digital-input-output-expansion-module","title":"GE Multilin UR6GV UR-6GV Digital Input\/Output Expansion Module","description":"\u003ch2\u003eGE Multilin UR6GV UR-6GV Digital Input\/Output Expansion Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin UR6GV\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR-6GV\u003c\/strong\u003e Digital Input\/Output Expansion Module, operates as a dedicated hardware component for signal acquisition and contact output control within the GE Multilin Universal Relay platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR6GV \/ UR-6GV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Grid Solutions \/ GE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C (-40 deg F to +140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input\/Output Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Relay Platforms\u003c\/td\u003e\n\u003ctd\u003eL90, G30, C70, T60, B30, N60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Position\u003c\/td\u003e\n\u003ctd\u003eUR chassis Slots F, G, H, or U depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eModular slide-in PCB card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8 opto-isolated inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm-A Outputs\u003c\/td\u003e\n\u003ctd\u003e2 normally open outputs with current sensing and optional voltage monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm-C Output\u003c\/td\u003e\n\u003ctd\u003e1 SPDT changeover contact output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatching Outputs\u003c\/td\u003e\n\u003ctd\u003e2 latching outputs for state retention during power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e17 to 300 V DC and AC control voltages depending on ordering configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Continuous Current\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Make and Carry Rating\u003c\/td\u003e\n\u003ctd\u003e30 A for 0.2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Break Capacity\u003c\/td\u003e\n\u003ctd\u003e0.3 A at 125 V DC, inductive load L\/R = 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e2000 V AC dielectric withstand for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe UR6GV module extends the Universal Relay hardware architecture by increasing discrete signal handling capacity through additional digital input and output channels. The opto-isolated input circuits provide electrical separation between field contact signals and relay logic processing. The module supports configurable I\/O density scaling within UR chassis configurations, allowing additional status monitoring points and control outputs to be integrated into protection and automation schemes.\u003c\/p\u003e\n\u003cp\u003eThe output section provides direct contact switching for breaker control, trip circuits, alarm functions, and interlocking logic. The latching output channels maintain defined states during loss of relay power for applications requiring retained lockout or memory functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the UR6GV module be installed in any UR relay slot?\u003cbr\u003eA: The UR6GV is installed in compatible Universal Relay chassis positions. Slot assignment depends on the specific relay hardware configuration and ordering arrangement.\u003c\/p\u003e\n\u003cp\u003eQ: Does the UR6GV provide electrical isolation between field signals and internal relay circuits?\u003cbr\u003eA: Yes. The digital input channels use opto-isolated circuits, and the module specifies 2000 V AC dielectric withstand isolation between inputs, outputs, and internal logic.\u003c\/p\u003e\n\u003cp\u003eQ: Are the output contacts suitable for direct breaker control applications?\u003cbr\u003eA: The module provides Form-A and Form-C contact outputs with specified current and switching ratings for control and trip circuit applications within the UR protection platform.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the UR6GV module into the designated Universal Relay chassis slot according to the relay hardware configuration.\u003c\/li\u003e\n\u003cli\u003eVerify the relay power supply and chassis grounding connections before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eRoute field contact wiring separately from high-voltage power conductors to reduce induced noise.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shield grounding practices for control wiring where electromagnetic interference is present.\u003c\/li\u003e\n\u003cli\u003eConfirm digital input voltage levels before connection to ensure compatibility with the selected 17 to 300 V DC input range.\u003c\/li\u003e\n\u003cli\u003eVerify output contact wiring against the protection scheme drawings before energizing breaker trip or control circuits.\u003c\/li\u003e\n\u003cli\u003eFollow manufacturer procedures for module replacement, firmware compatibility checks, and relay configuration verification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44494904819800,"sku":"UR6GV","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/UR6LV.jpg?v=1785750191","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-multilin-ur6gv-ur-6gv-digital-input-output-expansion-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}