{"product_id":"ge-multilin-ur5ah-ur-5ah-transducer-i-o-plug-in-module","title":"GE Multilin UR5AH UR-5AH Transducer I\/O Plug-in Module","description":"\u003ch2\u003eGE Multilin UR5AH UR-5AH Transducer I\/O Plug-in Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin UR-5AH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR5AH\u003c\/strong\u003e Transducer I\/O Module, operates as a dedicated hardware component for analog transducer signal acquisition and conversion within the GE Multilin Universal Relay (UR) Series platform. It interfaces external DC current and voltage signals with the relay processing system for metering, telemetry, and protection functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR5AH \/ UR-5AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in available data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTransducer Input\/Output (I\/O) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input \/ Output\u003c\/td\u003e\n\u003ctd\u003eAnalog DC current and voltage signals (mA, V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 2.0 kV RMS for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePlug-in card for GE UR chassis rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Multilin UR Backplane Communication and I\/O Integration\u003c\/h3\u003e\n\u003cp\u003eThe UR5AH module uses the modular architecture of the GE Multilin Universal Relay platform to transfer processed transducer data between external analog circuits and the relay CPU system. The plug-in card design supports I\/O density scaling by allowing additional functional modules to be installed within compatible UR chassis configurations.\u003c\/p\u003e\n\u003cp\u003eThe module provides galvanic and optical isolation between field signal circuits and internal relay electronics. This isolation structure reduces the influence of surge events and electromagnetic interference on signal processing paths. Diagnostic status information is exchanged with the main CPU card for continuous module condition monitoring.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for integration with UR Series relay platforms including C30, C60, D30, D60, F35, F60, G30, G60, T60 and related configurations supporting transducer I\/O functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the UR5AH designed for hot-swap installation?\u003cbr\u003eA: The UR5AH is a plug-in module designed for installation in a GE UR chassis slot. Hot-swap operation depends on the specific UR chassis configuration and operating procedure.\u003c\/p\u003e\n\u003cp\u003eQ: What type of signals can the UR5AH process?\u003cbr\u003eA: The module processes analog DC current and voltage signals from external transducers and instrumentation circuits.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module protected from electrical interference?\u003cbr\u003eA: The UR5AH uses galvanic and optical isolation between signal channels and internal relay circuitry to reduce electrical interference coupling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the UR5AH only in compatible GE Multilin Universal Relay chassis positions defined for transducer I\/O modules. Verify the chassis slot assignment before insertion.\u003c\/p\u003e\n\u003cp\u003eMaintain proper separation between analog signal wiring and high-voltage switching conductors. Use shielded cables for low-level analog signals where required by the installation environment, and connect cable shields according to the site grounding standard.\u003c\/p\u003e\n\u003cp\u003eConfirm connector seating and mechanical locking after module insertion. Check relay diagnostics after installation to verify module recognition, communication status, and channel operation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44497904140376,"sku":"UR5AH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/UR5DH_0f929988-8241-42ee-8237-19f011a500f5.jpg?v=1785832706","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-multilin-ur5ah-ur-5ah-transducer-i-o-plug-in-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}