{"product_id":"ge-multilin-mifpi55e000h00c-mifp-feeder-protection-relay","title":"GE Multilin MIFPI55E000H00C MIFP Feeder Protection Relay","description":"\u003ch2\u003eGE Multilin MIFPI55E000H00C MIFP Feeder Protection Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin MIFPI55E000H00C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMIFP\u003c\/strong\u003e Feeder Protection Relay, operates as a dedicated hardware component for feeder current protection and fault monitoring within Multilin MIF series power protection systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMIFPI55E000H00C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard MIF series relay case; exact dimensions not specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFeeder Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin MIF Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFeeder, line, and overcurrent protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A \/ 5 A configurable phase and ground current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eANSI 50, 51, 50N, 51N, 37, 46, 86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRS232 \/ USB front port, RS485 rear port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, IEC 60870-5-103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Interface\u003c\/td\u003e\n\u003ctd\u003eFront panel keypad with backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eFlush \/ panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Protection Integration\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin MIFPI55E000H00C applies microprocessor-based numerical processing for phase and ground current evaluation, programmable trip logic execution, and event recording. The relay supports integration into Substation Automation Systems (SAS) and SCADA networks through RS485 serial communication with Modbus RTU or IEC 60870-5-103 protocols.\u003c\/p\u003e\n\u003cp\u003eThe MIFP platform incorporates industrial protection functions including instantaneous and time overcurrent elements, neutral earth fault detection, negative sequence current monitoring, and programmable lockout output control. The relay architecture supports firmware-managed configuration, diagnostic monitoring, and fault record storage for maintenance analysis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What current input levels are supported by the MIFPI55E000H00C relay?\u003cbr\u003eA: The relay supports configurable phase and ground current inputs rated for 1 A or 5 A secondary current signals depending on the selected configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MIFPI55E000H00C support hot-swap replacement?\u003cbr\u003eA: The available documentation does not specify hot-swap capability. Installation and replacement should be performed with the relay isolated from energized circuits according to site procedures.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are available for configuration and monitoring?\u003cbr\u003eA: The relay provides a front maintenance interface using RS232 \/ USB and a rear RS485 serial interface supporting Modbus RTU and IEC 60870-5-103 communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the MIFPI55E000H00C in a suitable protective panel enclosure with correct mechanical support and terminal access clearance. Current transformer secondary wiring should maintain proper polarity and separation from control signal wiring to reduce measurement interference.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication cables where required by the installation environment. Cable shields should be terminated according to the grounding practice of the substation protection system. Maintain separation between current input circuits, auxiliary power wiring, and low-level communication lines to minimize electrical noise coupling.\u003c\/p\u003e\n\u003cp\u003eBefore energization, verify CT wiring polarity, auxiliary supply voltage range, digital input states, output relay logic configuration, and communication addressing parameters. Confirm protection settings against approved protection coordination documentation before placing the relay into service.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44547777396824,"sku":"MIFPI55E000H00C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/MIFIIPI51E10HI00.jpg?v=1786353186","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-multilin-mifpi55e000h00c-mifp-feeder-protection-relay","provider":"IndustriaX Limited","version":"1.0","type":"link"}