{"product_id":"ge-multilin-f650bfbf1g0hice-feeder-protection-relay","title":"GE Multilin F650BFBF1G0HICE Feeder Protection Relay","description":"\u003ch2\u003eGE Multilin F650BFBF1G0HICE Feeder Protection Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin F650BFBF1G0HICE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF650\u003c\/strong\u003e Feeder Protection Relay, operates as a dedicated hardware component for feeder protection, breaker control, and electrical measurement execution within GE Multilin 650 series protection networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF650BFBF1G0HICE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGE Multilin 650 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 VA nominal, 45 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFeeder Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Power Supply\u003c\/td\u003e\n\u003ctd\u003e110-250 V DC \/ 120-230 V AC high range supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003eUniversal CT inputs, 1 A \/ 5 A nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Inputs\u003c\/td\u003e\n\u003ctd\u003eAC voltage inputs, 275 V AC maximum nominal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e16 configurable digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e8 programmable output relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Communication\u003c\/td\u003e\n\u003ctd\u003e10\/100 Base-TX Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850 Edition 2, Modbus RTU\/TCP, DNP3, IEC 60870-5-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Interface\u003c\/td\u003e\n\u003ctd\u003e4 lines x 20 characters alphanumeric display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Protection\u003c\/td\u003e\n\u003ctd\u003eHarsh environment conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Interface\u003c\/td\u003e\n\u003ctd\u003eEnhanced display with front USB \/ serial configuration port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003eGreater than 100 ms typical after supply loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Multilin Feeder Protection and IEC 61850 Communication Features\u003c\/h3\u003e\n\u003cp\u003eThe F650BFBF1G0HICE integrates feeder protection logic, bay control functions, and communication processing within the GE Multilin 650 platform. The relay supports deterministic protection processing for ANSI functions including 50\/51 phase overcurrent, 50N\/51N ground overcurrent, 67\/67N directional overcurrent, 27\/59 voltage protection, 81 frequency protection, 50BF breaker failure, and 79 autoreclose control.\u003c\/p\u003e\n\u003cp\u003eThe integrated logic engine supports IEC 61131-3 programmable control functions for interlocking, transfer schemes, load shedding, and breaker control sequences. Communication functions include IEC 61850 Edition 2, Modbus RTU\/TCP, DNP3, and IEC 60870-5-104 protocol operation through the configured communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F650BFBF1G0HICE support hot-swap replacement during energized operation?\u003cbr\u003eA: The available documentation does not specify hot-swap capability. Replacement should follow standard protection relay isolation procedures with auxiliary supply and field wiring disconnected before removal.\u003c\/p\u003e\n\u003cp\u003eQ: What is the digital input and output hardware capacity of this configuration?\u003cbr\u003eA: The configuration includes 16 configurable digital inputs and 8 programmable relay outputs. Input filtering and output assignment are configured through the relay settings.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication interfaces are supported by this model configuration?\u003cbr\u003eA: This model supports IEC 61850 Edition 2, Modbus RTU\/TCP, DNP3, and IEC 60870-5-104 communication protocols through its configured Ethernet and serial interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the relay in a suitable protection panel enclosure with controlled grounding, ventilation, and access clearance according to the installation requirements of the GE Multilin 650 series.\u003c\/p\u003e\n\u003cp\u003eTerminate CT and VT wiring using dedicated protection terminal blocks. Maintain separation between low-level communication wiring and high-energy current or voltage circuits to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConnect the protective earth terminal using an appropriate grounding conductor. Apply shield grounding practices for communication cables according to the selected protocol installation standard.\u003c\/p\u003e\n\u003cp\u003eVerify auxiliary supply polarity and voltage range before energization. The HI power supply option accepts 110-250 V DC and 120-230 V AC input ranges within the specified operating limits.\u003c\/p\u003e\n\u003cp\u003ePerform secondary injection testing after installation to verify protection elements, trip outputs, breaker control logic, and communication data exchange.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44511846826072,"sku":"F650BFBF1G0HICE","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F650GNFBF1G0HICE.jpg?v=1786093696","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-multilin-f650bfbf1g0hice-feeder-protection-relay","provider":"IndustriaX Limited","version":"1.0","type":"link"}