{"product_id":"ge-multilin-369-hi-r-m-0-0-h-e-motor-protection-relay","title":"GE Multilin 369-HI-R-M-0-0-H-E Motor Protection Relay","description":"\u003ch2\u003eGE Multilin 369-HI-R-M-0-0-H-E Motor Protection Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin 369-HI-R-M-0-0-H-E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e369\u003c\/strong\u003e Motor Protection Relay, operates as a dedicated hardware component for AC motor protection, measurement, and control execution within industrial electrical protection networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-R-M-0-0-H-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.95 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e29.6 cm H x 10.7 cm W x 20.5 cm L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 10-15 W, maximum 25 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Input\u003c\/td\u003e\n\u003ctd\u003e50-300 VDC or 60-265 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eThermal overload, jam\/stall, undercurrent, phase reversal, current unbalance, ground fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A CT selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Inputs\u003c\/td\u003e\n\u003ctd\u003e50 to 240 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 12 RTD inputs through external module integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003eConfigurable 4-20 mA or 0-1 mA outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003eOptically isolated programmable inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003eForm-C SPDT contacts, 10 A continuous at 250 VAC \/ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet 10Base-T RJ45, Modbus TCP\/IP, RS485 Modbus RTU, front RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Communication Functions\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin 369-HI-R-M-0-0-H-E integrates motor management functions with PLC and DCS communication systems through Ethernet and serial communication interfaces. The Ethernet option provides Modbus TCP\/IP connectivity for supervisory monitoring and control networks. The relay supports deterministic data exchange for motor status, protection events, metering values, and diagnostic records.\u003c\/p\u003e\n\u003cp\u003eThe firmware architecture supports configuration storage, event recording, waveform capture, and maintenance diagnostics. The hardware platform includes communication ports for integration with engineering software and industrial control systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 369-HI-R-M-0-0-H-E support hot-swap replacement?\u003cbr\u003eA: The relay is designed as a panel-mounted protection device. Hot-swap operation is not specified. Power isolation and proper shutdown procedures are required before removal or replacement.\u003c\/p\u003e\n\u003cp\u003eQ: What communication protocols are available on this model?\u003cbr\u003eA: The unit provides Ethernet 10Base-T communication with Modbus TCP\/IP, rear RS485 communication with Modbus RTU, and a front RS232 configuration interface.\u003c\/p\u003e\n\u003cp\u003eQ: How are motor thermal and fault conditions recorded?\u003cbr\u003eA: The relay stores trip records, alarm logs, motor start records, self-test events, and waveform capture data for diagnostic review.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the relay in a suitable protective enclosure with wiring separation between power circuits, CT inputs, voltage sensing circuits, and communication cables.\u003c\/p\u003e\n\u003cp\u003eUse shielded communication wiring where required by the installation environment. Terminate cable shields according to the control system grounding design to reduce electrical noise coupling.\u003c\/p\u003e\n\u003cp\u003eVerify CT polarity, phase sequence, and voltage input wiring before energizing the relay. Confirm control power compatibility with the selected supply range.\u003c\/p\u003e\n\u003cp\u003eFor harsh environment installations, inspect the conformal coated electronic assembly condition and maintain enclosure protection against moisture, conductive dust, and corrosive contaminants.\u003c\/p\u003e\n\u003cp\u003eMaintain appropriate clearance for rear terminal access and ensure terminal connections are mechanically secured before commissioning.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44511750455384,"sku":"369-HI-R-M-0-0-H-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/369B1841G01305.jpg?v=1785923647","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-multilin-369-hi-r-m-0-0-h-e-motor-protection-relay","provider":"IndustriaX Limited","version":"1.0","type":"link"}