{"product_id":"ge-is230sttch1a-simplex-thermocouple-input-terminal-board","title":"GE IS230STTCH1A Simplex Thermocouple Input Terminal Board","description":"\u003ch2\u003eGE IS230STTCH1A Simplex Thermocouple Input Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS230STTCH1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS230STTCH1A\u003c\/strong\u003e Simplex Thermocouple Input Terminal Board, operates as a dedicated hardware component for thermocouple temperature signal acquisition within GE Mark VI\/Mark VIe turbine control systems. The board provides conditioned temperature inputs from field thermocouple sensors to controller processing channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS230STTCH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI \/ Mark VIe Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSimplex Thermocouple Input Terminal Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e24 thermocouple input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouple Types\u003c\/td\u003e\n\u003ctd\u003eType E, J, K, S, T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conditioning\u003c\/td\u003e\n\u003ctd\u003eEMI filtering, linearization, and scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation\u003c\/td\u003e\n\u003ctd\u003eIntegrated CJC circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Interface\u003c\/td\u003e\n\u003ctd\u003eBarrier terminal strips for direct thermocouple wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VI rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 60584 thermocouple standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Signal Processing and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IS230STTCH1A is designed for GE Mark VI\/Mark VIe control architectures, providing thermocouple signal termination and temperature measurement interface functions. The board processes multiple temperature input channels through signal conditioning circuits, including cold junction compensation, linearization, and EMI filtering.\u003c\/p\u003e\n\u003cp\u003eThe terminal board supports I\/O density scaling within Mark VI control cabinets by combining 24 thermocouple input points into a single simplex interface assembly. Firmware flash compatibility and communication behavior depend on the connected GE controller and I\/O processing hardware.\u003c\/p\u003e\n\u003cp\u003eChannel isolation separates individual temperature measurement circuits from adjacent signals and control electronics, reducing interference during analog temperature acquisition.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which thermocouple types are supported by the IS230STTCH1A?\u003cbr\u003eA: The board supports Type E, J, K, S, and T industrial thermocouple inputs.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the CJC function on the IS230STTCH1A?\u003cbr\u003eA: The cold junction compensation circuit corrects thermocouple reference junction effects to improve temperature measurement processing.\u003c\/p\u003e\n\u003cp\u003eQ: How many temperature input channels are available on the IS230STTCH1A?\u003cbr\u003eA: The board provides 24 thermocouple input channels in simplex configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS230STTCH1A in the designated GE Mark VI\/Mark VIe rack position and confirm proper mechanical seating before connecting field wiring.\u003c\/p\u003e\n\u003cp\u003eUse thermocouple extension cables matching the installed thermocouple type. Maintain separation between temperature signal wiring and high-current switching or power cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConnect cable shields according to the control cabinet grounding standard. Verify thermocouple polarity, terminal identification, and channel assignments before system startup.\u003c\/p\u003e\n\u003cp\u003eInspect terminal strip connections and field cable insulation during maintenance operations. Avoid routing thermocouple wiring near sources of electrical noise such as contactors, motors, and power converters.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44407795875928,"sku":"IS230STTCH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS230SNHRH2A.jpg?v=1784624380","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is230sttch1a-simplex-thermocouple-input-terminal-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}