{"product_id":"ge-is200worbh1a-digital-output-register-board","title":"GE IS200WORBH1A Digital Output Register Board","description":"\u003ch2\u003eGE IS200WORBH1A Digital Output Register Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic digital output register interfacing in the Mark VI Speedtronic turbine control system, the \u003cstrong\u003eGE IS200WORBH1A\u003c\/strong\u003e (\u003cstrong\u003eIS200WORB\u003c\/strong\u003e Digital Output Register Board) provides direct physical\/electrical execution for controller output signals, relay interfaces, and field device switching circuits.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IS200WORBH1A identification defines a GE Mark VI Speedtronic control board assembly. The available documentation identifies the complete ordering designation as IS200WORBH1A. No additional suffix segmentation details are specified for separate hardware variants.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Element\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIS200\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI board family identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWORB\u003c\/td\u003e\n\u003ctd\u003eWrite-Only Register Board function designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH1A\u003c\/td\u003e\n\u003ctd\u003eHardware revision and assembly identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200WORBH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm x 150 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic turbine control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Function\u003c\/td\u003e\n\u003ctd\u003eDigital output register interface board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTTL logic levels with optical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e5 VDC logic, field-driven through external drivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 1 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eRibbon connectors to controller backplane, screw terminals for field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eOvervoltage suppression and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003ePanel or DIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, UL 508, CE industrial standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Output Register Interface and Control Logic\u003c\/h3\u003e\n\u003cp\u003eThe IS200WORBH1A functions as a digital output interface between the Mark VI controller and external field devices. The board receives register-based output commands and transfers switching signals through isolated output channels.\u003c\/p\u003e\n\u003cp\u003eThe GE Mark VI platform uses deterministic controller communication paths for output execution. The board design supports firmware-controlled register operations and digital I\/O density scaling within the controller rack architecture.\u003c\/p\u003e\n\u003cp\u003eOptically isolated output channels separate controller-side logic circuits from field-side loads. Overvoltage suppression and short-circuit protection circuits are incorporated to reduce electrical stress during relay, solenoid, and contactor operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of output signals does the IS200WORBH1A provide?\u003cbr\u003eA: The board provides 32 digital outputs using TTL logic levels with optical isolation for interfacing external field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200WORBH1A support direct high-voltage field loads?\u003cbr\u003eA: No. The board provides logic-level output interfacing. Field devices require external drivers or interface components according to the control system design.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interface connects the board to the Mark VI controller?\u003cbr\u003eA: The board uses ribbon connectors for controller rack interfacing and screw terminals for field wiring connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200WORBH1A according to the Mark VI cabinet hardware arrangement. Verify board orientation, connector alignment, and terminal identification before connecting field wiring.\u003c\/p\u003e\n\u003cp\u003eRoute digital output wiring separately from high-voltage power conductors and high-current switching circuits where possible. Use appropriate grounding methods for cable shields and maintain separation between controller communication wiring and field power wiring.\u003c\/p\u003e\n\u003cp\u003eInspect ribbon connector engagement and terminal screw tightness during installation. Confirm output channel mapping before energizing connected relays, solenoids, or contactor circuits.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44403784253528,"sku":"IS200WORBH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200AEPAH1A2_841c4e5d-3f45-49de-abe9-b4d677838967.jpg?v=1784542789","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200worbh1a-digital-output-register-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}