{"product_id":"ge-is200vturh1bab-primary-turbine-protection-board","title":"GE IS200VTURH1BAB Primary Turbine Protection Board","description":"\u003ch2\u003eGE IS200VTURH1BAB Primary Turbine Protection Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for turbine overspeed monitoring and emergency trip execution in GE Mark VI Speedtronic systems, the \u003cstrong\u003eGE IS200VTURH1BAB\u003c\/strong\u003e (\u003cstrong\u003eIS200VTUR\u003c\/strong\u003e Primary Turbine Protection Board) provides direct physical\/electrical execution for speed signal acquisition, flame detector monitoring, and trip relay control functions. The board processes magnetic pickup inputs, voltage monitoring channels, and protection signals for turbine shutdown logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VTURH1BAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 x 9 x 3 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 VDC operational input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrimary Turbine Protection Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e6 voltage monitoring channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Inputs\u003c\/td\u003e\n\u003ctd\u003e4 passive magnetic pickup inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e2 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Speed Detection\u003c\/td\u003e\n\u003ctd\u003e2 RPM turning gear measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Detector Inputs\u003c\/td\u003e\n\u003ctd\u003e8 Geiger-Mueller inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Relay Outputs\u003c\/td\u003e\n\u003ctd\u003e3 primary overspeed trip relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit precision measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 50 ms for trip initiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Range\u003c\/td\u003e\n\u003ctd\u003e+\/-5 V signal tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSimplex and TMR configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Networks and Protection Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200VTURH1BAB performs turbine protection signal processing through dedicated hardware channels within the Mark VI Speedtronic architecture. The board receives speed feedback from passive magnetic pickups, processes frequency measurement signals, and controls overspeed trip relay outputs based on configured protection logic.\u003c\/p\u003e\n\u003cp\u003eThe module supports simplex and triple modular redundancy (TMR) system configurations. In TMR arrangements, protection decisions are coordinated through redundant hardware paths to maintain continuous turbine shutdown monitoring. The board also processes flame detector inputs and shaft voltage\/current monitoring signals for protection status evaluation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of speed input signals are supported by the IS200VTURH1BAB?\u003cbr\u003eA: The board supports four passive magnetic pickup inputs with a measurable frequency range of 2 Hz to 20 kHz for turbine speed monitoring.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200VTURH1BAB support redundant turbine protection architectures?\u003cbr\u003eA: Yes. The board supports both simplex and TMR configurations within the GE Mark VI Speedtronic control system.\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of the trip relay outputs on this board?\u003cbr\u003eA: The three primary overspeed trip relays provide electrical switching outputs for initiating turbine shutdown actions when protection limits are exceeded.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200VTURH1BAB in the designated GE Mark VI rack location according to the turbine control cabinet hardware arrangement. Verify that terminal boards, field wiring, and rack connections match the configured simplex or TMR architecture before energizing the system.\u003c\/p\u003e\n\u003cp\u003eRoute magnetic pickup, flame detector, and analog monitoring cables separately from high-voltage switching conductors to reduce electrical interference. Use appropriate shield termination practices for low-level measurement circuits and connect cable shields according to the cabinet grounding design.\u003c\/p\u003e\n\u003cp\u003eBefore operation, verify input channel assignment, relay output wiring, and protection signal polarity. Confirm that all field devices connected to the board provide signals within the specified electrical input range.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44357447778392,"sku":"IS200VTURH1BAB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200VTURH1BAB_0587de29-e452-49dd-92d1-eeb2030b767b.jpg?v=1783677312","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200vturh1bab-primary-turbine-protection-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}