{"product_id":"ge-is200vcmih1bcd-vme-communication-interface-module","title":"GE IS200VCMIH1BCD VME Communication Interface Module","description":"\u003ch2\u003eGE IS200VCMIH1BCD VME Communication Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic VME bus communication and synchronization in GE Mark VI Speedtronic turbine control platforms, the \u003cstrong\u003eGE IS200VCMIH1BCD\u003c\/strong\u003e (\u003cstrong\u003eIS200VCMI\u003c\/strong\u003e VME Communication Interface Module) provides direct physical data exchange execution between controllers, I\/O modules, and processors.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VCMIH1BCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e266 x 191 x 63 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVME Communication Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e6U VME single-slot board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eVME bus master and communication controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 5 VDC for VME bus operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eIONet with IEEE 1588 synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Management\u003c\/td\u003e\n\u003ctd\u003eSIFT (Software Implemented Fault Tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSimplex and TMR configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Interface\u003c\/td\u003e\n\u003ctd\u003eLED status, fault, and communication indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Communication and Redundancy Architecture\u003c\/h3\u003e\n\u003cp\u003eThe IS200VCMIH1BCD functions as the VME bus master within the Mark VI control architecture, coordinating communication timing between processor modules, I\/O boards, and turbine control subsystems. The module manages deterministic data transfer through the VME backplane and supports IONet synchronization using IEEE 1588 timing functions.\u003c\/p\u003e\n\u003cp\u003eThe VCMI module supports firmware flash compatibility within Mark VI controller assemblies and provides communication velocity management across the VME bus infrastructure. In TMR configurations, multiple VCMI modules exchange synchronized data and apply SIFT voting logic to maintain fault-tolerant communication execution.\u003c\/p\u003e\n\u003cp\u003eThe module provides board-level diagnostics through LED indicators for operating state, communication activity, and fault identification. It is installed in compatible VME rack assemblies requiring coordinated control data exchange between redundant turbine control modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary communication function of the IS200VCMIH1BCD?\u003c\/p\u003e\n\u003cp\u003eA: The IS200VCMIH1BCD operates as a VME bus master, controlling communication exchange between Mark VI processors, I\/O modules, and other VME-based control boards.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200VCMIH1BCD support TMR system configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports simplex and triple modular redundancy configurations, including synchronized operation with redundant Mark VI controller racks.\u003c\/p\u003e\n\u003cp\u003eQ: What network synchronization method is used by the IS200VCMIH1BCD?\u003c\/p\u003e\n\u003cp\u003eA: The module supports IONet communication with IEEE 1588 synchronization for deterministic timing coordination across connected turbine control modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200VCMIH1BCD into the assigned 6U VME rack slot according to the Mark VI hardware configuration documentation. Remove rack power before module insertion or removal to avoid electrical stress on VME connectors.\u003c\/p\u003e\n\u003cp\u003eVerify VME backplane alignment, board seating, and rack addressing before applying system power. Route communication wiring separately from high-current switching conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eMaintain proper cabinet grounding practices and verify shield termination for external communication cables. After installation, confirm LED status indicators, board identification, and controller communication diagnostics before returning the turbine control system to service.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44357141626968,"sku":"IS200VCMIH1BCD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200VCMIH1BCD_776c7886-bbf8-4f78-bae2-8453b317e0bb.jpg?v=1783671413","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200vcmih1bcd-vme-communication-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}