{"product_id":"ge-is200vaich1cba-analog-input-output-board","title":"GE IS200VAICH1CBA Analog Input\/Output Board","description":"\u003ch2\u003eGE IS200VAICH1CBA Analog Input\/Output Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200VAICH1CBA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200VAIC\u003c\/strong\u003e Analog Input\/Output Board, provides direct analog signal conversion and actuator output processing within GE Mark VI Speedtronic turbine control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VAICH1CBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output (VAIC) Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e20 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, +\/-5 V, +\/-10 V, 0-1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA or 4-20 mA actuator drive outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit D\/A converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003e32-bit VMEbus P1\/P2 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003e10BaseT\/100BaseTX Ethernet RJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Time\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e128 MB flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSimplex and TMR configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI VME Analog Processing Architecture\u003c\/h3\u003e\n\u003cp\u003eThe IS200VAICH1CBA performs analog input acquisition and analog output generation between field devices and Mark VI turbine control processors. The board accepts current and voltage feedback signals from sensors and transmits converted digital values through the VME backplane communication structure.\u003c\/p\u003e\n\u003cp\u003eThe module supports I\/O density scaling within Mark VI rack architectures by combining multiple analog input channels and actuator output channels on a single VME board. The TMR configuration distributes field signal processing across redundant boards, allowing system diagnostics to isolate a failed channel assembly.\u003c\/p\u003e\n\u003cp\u003eThe IS200VAICH1CBA supports firmware flash compatibility within the Mark VI platform and communicates through the VMEbus interface for deterministic controller data exchange. The board integrates with compatible terminal boards including TBAIH1B\/C and DTAI assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What analog conversion functions are provided by the IS200VAICH1CBA?\u003c\/p\u003e\n\u003cp\u003eA: The board provides 16-bit analog-to-digital conversion for input channels and 12-bit digital-to-analog conversion for output channels connected to actuator control circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200VAICH1CBA support redundant control configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports simplex and triple modular redundant (TMR) configurations within compatible GE Mark VI control racks.\u003c\/p\u003e\n\u003cp\u003eQ: What type of backplane communication does this board use?\u003c\/p\u003e\n\u003cp\u003eA: The IS200VAICH1CBA uses the GE Mark VI VME rack architecture through P1\/P2 VMEbus connectors for controller communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200VAICH1CBA into the designated double-slot VME rack position according to the Mark VI hardware configuration. Verify rack power removal before board insertion or removal to prevent connector damage and unintended electrical conditions.\u003c\/p\u003e\n\u003cp\u003eConnect analog field wiring through the specified terminal boards and maintain cable separation between low-level analog signals and high-current switching conductors. Use shielded instrumentation cable where required, with cable shields terminated according to cabinet grounding practices.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify channel assignments, terminal board compatibility, redundancy configuration, and controller recognition through Mark VI diagnostic tools. Check LED status indicators and communication feedback after installation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44357132681304,"sku":"IS200VAICH1CBA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200VAOCH1C_8e1998ac-3383-42be-990c-b10ed7903738.jpg?v=1783671210","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200vaich1cba-analog-input-output-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}