{"product_id":"ge-is200trlys1bgg-relay-output-terminal-board","title":"GE IS200TRLYS1BGG Relay Output Terminal Board","description":"\u003ch2\u003eGE IS200TRLYS1BGG Relay Output Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200TRLYS1BGG\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TRLYS1B\u003c\/strong\u003e Relay Output Terminal Board, operates as a dedicated hardware component for relay signal switching and external device control within GE Mark VI and Mark VIe Speedtronic control systems. It provides isolated relay outputs for actuators, alarms, trip circuits, and auxiliary equipment interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRLYS1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 160 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in available data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ Mark VIe Speedtronic Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Channels\u003c\/td\u003e\n\u003ctd\u003e12-16 independent Form C (SPDT) relay outputs depending on revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eMagnetic plug-in relays with transparent protective covers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 5 A at 250 VAC resistive load; 2 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC nominal; 250 VAC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC with coil diagnostics enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=10 ms activation; \u0026lt;=5 ms release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical and physical relay isolation; channel-to-channel withstand \u0026gt;=500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eMOV surge suppression per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Filtering\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 ms switching filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL\/cUL Class I Div 2, IEC 61010, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VIe Relay Output Isolation and Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRLYS1BGG provides relay-based output execution within GE turbine control architectures by converting controller commands into isolated electrical switching signals. The terminal board supports relay outputs for trip circuits, solenoids, alarms, and auxiliary equipment control.\u003c\/p\u003e\n\u003cp\u003eThe relay output architecture supports simplex, dual, and TMR system configurations. The board incorporates channel-level diagnostics for coil condition monitoring, contact status evaluation, and voltage verification. Communication of diagnostic information is performed through GE ToolboxST configuration and maintenance software.\u003c\/p\u003e\n\u003cp\u003eThe board uses firmware flash compatibility and Mark VIe hardware identification procedures to maintain correct configuration matching between terminal boards and controller assemblies. MOV-based surge suppression and relay isolation structures provide switching protection against transient electrical disturbances.\u003c\/p\u003e\n\u003cp\u003eThe relay interface supports deterministic output execution within GE Speedtronic systems, while the isolated relay channels provide separation between controller logic circuits and external field devices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of relay outputs are provided by the IS200TRLYS1BGG?\u003cbr\u003eA: The terminal board provides independent Form C (SPDT) magnetic relay outputs for switching external field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Does the terminal board support redundant control configurations?\u003cbr\u003eA: Yes. The IS200TRLYS1BGG supports simplex, dual, and TMR configurations within compatible Mark VI and Mark VIe architectures.\u003c\/p\u003e\n\u003cp\u003eQ: How are relay output circuits protected from electrical transients?\u003cbr\u003eA: Each relay channel includes MOV surge suppression components to reduce transient voltage effects during switching operations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200TRLYS1BGG according to GE Mark VI or Mark VIe cabinet installation procedures. Verify terminal board connector placement, relay module seating, and field wiring termination before applying power.\u003c\/p\u003e\n\u003cp\u003eUse appropriate field wiring separation between relay output circuits and low-level signal cables. Maintain shield grounding practices according to the cabinet grounding design and avoid routing relay conductors adjacent to sensitive analog communication wiring.\u003c\/p\u003e\n\u003cp\u003eConfirm relay contact ratings match the connected external load characteristics before commissioning. Verify coil voltage configuration, diagnostic settings, and ToolboxST hardware identification data before placing the control system into operation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44350077993048,"sku":"IS200TRLYS1BGG","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200TRLYH1D.jpg?v=1783587769","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200trlys1bgg-relay-output-terminal-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}