{"product_id":"ge-is200tregh1a-emergency-trip-terminal-board","title":"GE IS200TREGH1A Emergency Trip Terminal Board","description":"\u003ch2\u003eGE IS200TREGH1A Emergency Trip Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for emergency trip solenoid signal termination in GE Mark VI Speedtronic turbine control systems, the \u003cstrong\u003eGE IS200TREGH1A\u003c\/strong\u003e (\u003cstrong\u003eIS200TREG\u003c\/strong\u003e Emergency Trip Terminal Board) provides direct physical\/electrical execution for trip command distribution, solenoid driver interfacing, and protective circuit isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TREGH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eEmergency Trip Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Function\u003c\/td\u003e\n\u003ctd\u003eTrip solenoid termination and emergency trip interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Trip Solenoids\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Inputs\u003c\/td\u003e\n\u003ctd\u003e125 VDC \/ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Outputs\u003c\/td\u003e\n\u003ctd\u003eSupports 3 trip solenoid drivers, 24 VDC coil typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid Response Time\u003c\/td\u003e\n\u003ctd\u003e0.1 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A at 30 VDC; 0.5 A at 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between trip circuits and control logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eScrew terminals for field wiring; ribbon connectors to control rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eSurge suppression, arc suppression, fault isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mount or DIN-rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control I\/O Scaling and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200TREGH1A operates as a terminal interface assembly within the GE Mark VI Speedtronic protection architecture. The board receives trip commands from the controller, interfaces with emergency trip circuits, and controls energizing or de-energizing of turbine trip solenoids.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control I\/O density scaling by providing multiple isolated trip output channels within a dedicated emergency shutdown interface. Galvanic isolation separates external trip devices from controller logic circuits, reducing electrical coupling between field protection wiring and internal control electronics.\u003c\/p\u003e\n\u003cp\u003eThe terminal board incorporates protection functions including surge suppression, contact arc suppression, and fault isolation. Its interface structure is designed for integration with Mark VI trip logic modules and associated turbine protection hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many trip solenoid circuits can the IS200TREGH1A interface?\u003cbr\u003eA: The board supports three trip solenoid driver channels and three relay outputs for emergency trip circuit control.\u003c\/p\u003e\n\u003cp\u003eQ: What input voltage levels are supported for trip commands?\u003cbr\u003eA: The module supports trip input circuits at 24 VDC and 125 VDC levels according to the provided specifications.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200TREGH1A directly provide mechanical turbine shutdown action?\u003cbr\u003eA: No. The board provides electrical termination and switching interface functions for trip solenoids. Mechanical shutdown is performed by the connected turbine protection devices.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200TREGH1A according to GE Mark VI cabinet drawings and verify terminal assignments before connecting emergency trip wiring.\u003c\/p\u003e\n\u003cp\u003eRoute trip solenoid cables separately from high-current switching conductors to reduce electromagnetic interference. Use appropriate grounding and shielding practices for signal wiring according to the control cabinet design.\u003c\/p\u003e\n\u003cp\u003eCheck screw terminal torque, ribbon connector engagement, and field wiring polarity before commissioning. Verify trip circuit continuity and insulation condition during installation and maintenance procedures.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44403632144472,"sku":"IS200TREGH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200TREGH1BDB1_d8cb8a7e-a151-4dc3-b03a-10035171df4c.jpg?v=1784540148","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200tregh1a-emergency-trip-terminal-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}