{"product_id":"ge-is200srlyh2a-relay-output-terminal-board","title":"GE IS200SRLYH2A Relay Output Terminal Board","description":"\u003ch2\u003eGE IS200SRLYH2A Relay Output Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200SRLYH2A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200SRLY\u003c\/strong\u003e Relay Output Terminal Board, operates as a dedicated hardware component for relay signal switching and field device control within the GE Mark VIe and EX2100 turbine control systems. The board converts controller output commands into relay contact actions for external circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200SRLYH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe \/ EX2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSimplex Relay Output Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Channels\u003c\/td\u003e\n\u003ctd\u003e12 relay channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Type\u003c\/td\u003e\n\u003ctd\u003eRelay output interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eElectrical isolation between relay circuits and control logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ EX2100 chassis slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eSurface Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e480 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Industrial Relay Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe IS200SRLYH2A provides relay output termination functions within the GE Mark VIe industrial control architecture. The board receives low-level controller commands and transfers them through relay contacts to external field devices such as solenoids, alarms, and turbine auxiliary circuits.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control platform integration through GE I\/O architectures and maintains firmware flash compatibility within the Mark VIe system environment. Relay output density scaling allows multiple discrete control circuits to be managed through a single terminal board assembly.\u003c\/p\u003e\n\u003cp\u003eThe surface mount design provides compact relay signal routing and supports electrical separation between controller logic and field switching circuits. The relay interface is used for discrete command execution in turbine protection, excitation control, and interlock applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many relay output channels are available on the IS200SRLYH2A?\u003cbr\u003eA: The board provides 12 relay output channels according to the specified Mark VIe configuration.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field devices can be controlled by the IS200SRLYH2A?\u003cbr\u003eA: The relay outputs can interface with discrete field devices including solenoids, alarms, and auxiliary switching circuits.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting options are supported by the IS200SRLYH2A?\u003cbr\u003eA: The board supports installation in the EX2100 chassis configuration or designated DIN rail mounting arrangements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200SRLYH2A in the assigned Mark VIe or EX2100 control cabinet position and verify relay terminal identification before connecting field wiring. Confirm contact ratings and load requirements before energizing connected circuits.\u003c\/p\u003e\n\u003cp\u003eUse separated routing for relay output wiring and low-level signal cables to reduce electrical interference. Connect protective grounding according to cabinet design requirements and verify relay contact status during commissioning procedures.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44391064961112,"sku":"IS200SRLYH2A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200SRLYH2ABA_0058e0b9-8c15-4f13-a35e-0f002386eae3.jpg?v=1784276391","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200srlyh2a-relay-output-terminal-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}