{"product_id":"ge-is200jpdeg1aaa-mark-vie-dc-battery-power-distribution-board","title":"GE IS200JPDEG1AAA Mark VIe DC Battery Power Distribution Board","description":"\u003ch2\u003eGE IS200JPDEG1AAA Mark VIe DC Battery Power Distribution Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200JPDEG1AAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200JPDEG1AAA\u003c\/strong\u003e DC Battery Power Distribution Board, operates as a dedicated hardware component for DC power distribution, voltage feedback, and fault monitoring within the GE Mark VIe Speedtronic Turbine Control System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200JPDEG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Battery Power Distribution Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC nominal 24 VDC or 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution Channels\u003c\/td\u003e\n\u003ctd\u003e24 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rejection\u003c\/td\u003e\n\u003ctd\u003e60 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Sources\u003c\/td\u003e\n\u003ctd\u003eDual power supply input support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback Interface\u003c\/td\u003e\n\u003ctd\u003ePPDA I\/O pack voltage feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Type\u003c\/td\u003e\n\u003ctd\u003eFloating DC bus centered on earth through resistors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounting, vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eSurface-mount PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and DC Power Distribution Control\u003c\/h3\u003e\n\u003cp\u003eThe IS200JPDEG1AAA distributes DC power from battery supplies or rectifier sources to Mark VIe terminal boards and system loads. The board provides multiple distribution channels with input isolation and voltage feedback functions through the PPDA I\/O pack interface.\u003c\/p\u003e\n\u003cp\u003eThe module integrates with Mark VIe deterministic control architectures through configured power monitoring functions. Firmware flash compatibility within the system platform allows the controller to identify power distribution status and maintain configured diagnostic parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many DC distribution channels are available on the IS200JPDEG1AAA?\u003cbr\u003eA: The board provides 24 DC power distribution channels for connected Mark VIe system loads.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation level is provided by the IS200JPDEG1AAA input circuits?\u003cbr\u003eA: The board provides 1500 VAC input isolation between power circuits and connected system interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: How does the board provide voltage feedback information?\u003cbr\u003eA: Voltage feedback is provided through the PPDA I\/O pack interface for Mark VIe system monitoring functions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200JPDEG1AAA on the designated DIN rail mounting location with the board installed in the specified vertical orientation. Verify DC power input polarity and terminal connections before energizing the distribution circuit.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between DC power wiring and sensitive communication or signal cables. Ensure protective grounding and cabinet bonding connections follow the Mark VIe installation design.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify all connected power distribution channels, supply source configuration, and PPDA feedback wiring. Confirm voltage status and fault monitoring indications before enabling connected control hardware.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44377252102232,"sku":"IS200JPDEG1AAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200JPDDG1A.jpg?v=1784022263","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200jpdeg1aaa-mark-vie-dc-battery-power-distribution-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}