{"product_id":"ge-is200ehfch1aaa-high-frequency-communication-board","title":"GE IS200EHFCH1AAA High Frequency Communication Board","description":"\u003ch2\u003eGE IS200EHFCH1AAA High Frequency Communication Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed control data exchange in the GE Mark VI Speedtronic turbine control system, the \u003cstrong\u003eGE IS200EHFCH1AAA\u003c\/strong\u003e (\u003cstrong\u003eIS200EHFC\u003c\/strong\u003e High Frequency Communication Board) provides direct physical and electrical execution for VME backplane and IONet communication synchronization between turbine control modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EHFCH1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Frequency Communication Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eIONet, IEEE 1588 Precision Time Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eVMEbus P1\/P2 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC and +\/-15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eVME-style plug-in card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Mode Support\u003c\/td\u003e\n\u003ctd\u003eSimplex and TMR configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eConformal coating and transient suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Communication and Industrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe IS200EHFCH1AAA operates as a GE Mark VI communication interface board supporting deterministic data transfer between turbine controllers and I\/O modules. The board manages high-frequency communication paths through VMEbus P1\/P2 connections and IONet interfaces for synchronized control data exchange.\u003c\/p\u003e\n\u003cp\u003eFor GE industrial control architectures, the communication board supports firmware flash compatibility within the Mark VI platform and maintains coordinated timing through IEEE 1588 precision time protocol functions. The module architecture supports I\/O density scaling by allowing multiple control and acquisition modules to exchange synchronized data within simplex and triple modular redundant configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are supported by the IS200EHFCH1AAA?\u003cbr\u003eA: The board supports IONet communication and IEEE 1588 precision time protocol synchronization through the GE Mark VI control architecture.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS200EHFCH1AAA operate in redundant control configurations?\u003cbr\u003eA: Yes. The board supports simplex and triple modular redundant (TMR) system configurations within compatible Mark VI turbine control systems.\u003c\/p\u003e\n\u003cp\u003eQ: What type of backplane connection is used by the IS200EHFCH1AAA?\u003cbr\u003eA: The board uses VMEbus P1\/P2 connectors for connection to the Mark VI control rack backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200EHFCH1AAA into the designated VME rack slot within the GE Mark VI control cabinet. Verify connector alignment before insertion to prevent damage to the P1\/P2 backplane contacts.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between communication wiring and high-current power cables to reduce electromagnetic interference. Cable shields should be terminated according to cabinet grounding practices, with attention to avoiding ground loops.\u003c\/p\u003e\n\u003cp\u003eBefore system startup, confirm board seating, rack addressing, communication network continuity, and compatibility with installed Mark VI firmware configurations. Follow GE cabinet wiring documentation for grounding, module placement, and network routing requirements.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44357586583640,"sku":"IS200EHFCH1AAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200EHFCH1AAA.jpg?v=1783678952","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200ehfch1aaa-high-frequency-communication-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}