{"product_id":"ge-is200aepch1a-auxiliary-electronic-printed-circuit-module","title":"GE IS200AEPCH1A Auxiliary Electronic Printed Circuit Module","description":"\u003ch2\u003eGE IS200AEPCH1A Auxiliary Electronic Printed Circuit Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for auxiliary signal conditioning and interface processing in GE Speedtronic Mark VI\/Mark VIe turbine control systems, the \u003cstrong\u003eGE IS200AEPCH1A\u003c\/strong\u003e (\u003cstrong\u003eIS200AEPCH1A\u003c\/strong\u003e Auxiliary Electronic Printed Circuit Module) provides direct physical\/electrical execution for analog and digital I\/O handling within turbine control cabinets.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPCH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Electronic Printed Circuit (AEPC) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Speedtronic Mark VI \/ Mark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit industrial microprocessor, 400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e128 MB RAM, 64 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP, Ethernet\/IP, Profibus DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Base-T Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfibus Interface\u003c\/td\u003e\n\u003ctd\u003e1 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack mount, Mark VI chassis compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VIe Industrial Control Communication and I\/O Processing\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEPCH1A module performs auxiliary subsystem signal processing through configurable analog and digital channels. The module interfaces with turbine auxiliary circuits including lubrication, sealing, cooling, and emergency shutdown related signals.\u003c\/p\u003e\n\u003cp\u003eThe module supports Ethernet\/IP, Modbus TCP\/IP, and Profibus DP communication interfaces for data exchange with Mark VI\/Mark VIe control networks. Firmware flash compatibility and memory resources support module configuration management within the Speedtronic control architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signals can the IS200AEPCH1A process?\u003cbr\u003eA: The module provides 8 digital inputs, 8 digital outputs, and 4 analog input channels configured for 4-20 mA signal acquisition.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are available on the IS200AEPCH1A?\u003cbr\u003eA: The module provides two 10\/100 Base-T Ethernet ports and one Profibus interface, supporting Ethernet\/IP, Modbus TCP\/IP, and Profibus DP communication protocols.\u003c\/p\u003e\n\u003cp\u003eQ: What installation considerations apply to this module?\u003cbr\u003eA: The module should be installed in a compatible Mark VI chassis with correct rack alignment, grounding connection, and verified power supply polarity before system energization.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200AEPCH1A module into the designated GE Mark VI or Mark VIe rack position with the control cabinet power isolated. Verify chassis compatibility, connector alignment, and supply voltage polarity before applying power.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between analog signal wiring, communication cables, and high-current conductors to minimize electrical interference. Use shielded cables for low-level analog circuits and terminate shields according to the cabinet grounding design.\u003c\/p\u003e\n\u003cp\u003eEnsure mounting hardware provides proper mechanical retention and grounding continuity through the conductive mounting points. Confirm communication link status and I\/O channel operation after installation using the turbine control system diagnostic functions. \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44387718234200,"sku":"IS200AEPCH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200AEPCH1A_b6f6f898-5b35-4d9c-b4b4-7ab2da1df9be.jpg?v=1784191292","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-is200aepch1a-auxiliary-electronic-printed-circuit-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}