{"product_id":"ge-ds200slccg3a-mark-v-lan-communications-card","title":"GE DS200SLCCG3A Mark V LAN Communications Card","description":"\u003ch2\u003eGE DS200SLCCG3A Mark V LAN Communications Card\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200SLCCG3A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200SLCC\u003c\/strong\u003e LAN Communications Card, operates as a dedicated hardware component for LAN signal processing and communication interface control within the GE Mark V Speedtronic Turbine Control System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200SLCCG3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLAN Communications Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System Series\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eSLCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Processor\u003c\/td\u003e\n\u003ctd\u003eLAN Control Processor (LCP, U1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Storage\u003c\/td\u003e\n\u003ctd\u003eDual replaceable EPROM sockets (U6, U7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Exchange Memory\u003c\/td\u003e\n\u003ctd\u003eDual-Ported RAM (U5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Memory\u003c\/td\u003e\n\u003ctd\u003eRAM sockets U8 and U9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Interface\u003c\/td\u003e\n\u003ctd\u003e16-character alphanumeric LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Connectors\u003c\/td\u003e\n\u003ctd\u003e3PL and KPPL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eStandoff-mounted on SDCC parent board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Hardware\u003c\/td\u003e\n\u003ctd\u003eBerg jumpers (JP) and wire jumpers (WJ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Reference\u003c\/td\u003e\n\u003ctd\u003eGEI-100162B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network Communication Processing\u003c\/h3\u003e\n\u003cp\u003eThe DS200SLCCG3A performs LAN communication processing through its onboard LAN Control Processor (LCP). The processor manages local packet handling, communication filtering, and data transfer between the SLCC board and the associated Drive Control Processor through the 3PL interface.\u003c\/p\u003e\n\u003cp\u003eThe board uses dual-ported RAM to provide simultaneous memory access between the LCP and the parent SDCC control board. This architecture supports direct exchange of control and status data without requiring serial buffering through external communication devices.\u003c\/p\u003e\n\u003cp\u003eThe firmware architecture uses replaceable EPROM devices installed in U6 and U7 sockets. Replacement boards are supplied with empty EPROM sockets, requiring transfer of programmed EPROM devices from the existing board during field replacement operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the function of the DS200SLCCG3A KPPL connector?\u003cbr\u003eA: The KPPL connector provides the interface for an external programmer key module. It allows access to diagnostic displays, system status codes, and configuration information through the integrated display system.\u003c\/p\u003e\n\u003cp\u003eQ: Can the DS200SLCCG3A operate without transferred EPROM devices?\u003cbr\u003eA: The board requires the correct firmware stored in the EPROM devices installed at U6 and U7. Replacement installation requires transferring compatible programmed EPROM devices from the original SLCC board when applicable.\u003c\/p\u003e\n\u003cp\u003eQ: How is the DS200SLCCG3A configured for system operation?\u003cbr\u003eA: Hardware configuration is performed through factory and application-specific settings using Berg-type jumpers (JP) and wire jumpers (WJ) located on the PCB.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the DS200SLCCG3A directly onto the compatible SDCC parent control board using the specified standoff mounting arrangement.\u003c\/li\u003e\n\u003cli\u003eVerify that all EPROM devices are correctly transferred and seated before system power application.\u003c\/li\u003e\n\u003cli\u003eInspect the 3PL connector interface for proper alignment and mechanical engagement before installation.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between communication wiring and high-current power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eEnsure PCB handling procedures include ESD protection when installing or removing the communication card.\u003c\/li\u003e\n\u003cli\u003eConfirm jumper positions (JP and WJ) match the required system configuration before returning the turbine control cabinet to service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44484785963096,"sku":"DS200SLCCG3A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200SLCCG3AEF_a63eed49-b64f-4e64-b9b7-adfb3a6461ac.jpg?v=1785488231","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-ds200slccg3a-mark-v-lan-communications-card","provider":"IndustriaX Limited","version":"1.0","type":"link"}