{"product_id":"ge-ds200dtbag1aaa-terminal-board-assembly","title":"GE DS200DTBAG1AAA Terminal Board Assembly","description":"\u003ch2\u003eGE DS200DTBAG1AAA Terminal Board Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200DTBAG1AAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200DTBA\u003c\/strong\u003e Terminal Board Assembly, operates as a dedicated hardware component for field signal termination and electrical interfacing within the GE Mark V turbine control system. It provides physical connections for analog, digital, and trip circuit wiring between external devices and control rack electronics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200DTBAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Board Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eDTBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types Supported\u003c\/td\u003e\n\u003ctd\u003eAnalog signals, digital 24 VDC signals, trip solenoid signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC nominal field supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals, 2-level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e233 mm x 160 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive board, no onboard power processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control Interface and Signal Distribution\u003c\/h3\u003e\n\u003cp\u003eThe DS200DTBAG1AAA is a passive terminal interface board within the GE Mark V control architecture. It provides termination points for field wiring connected to turbine sensors, actuators, trip circuits, and protection devices. Signal routing is performed through terminal connections to associated processor and power interface boards.\u003c\/p\u003e\n\u003cp\u003eFor GE Mark V systems, the terminal interface supports structured I\/O wiring arrangements and connection compatibility with processor cards such as CPCA and power\/control boards such as LDCC. The board does not execute control logic and depends on connected controller hardware for signal processing and diagnostics.\u003c\/p\u003e\n\u003cp\u003eThe terminal assembly supports industrial control requirements including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eField signal termination and routing\u003c\/li\u003e\n\u003cli\u003eAnalog and digital I\/O connection\u003c\/li\u003e\n\u003cli\u003eTrip circuit wiring interface\u003c\/li\u003e\n\u003cli\u003eConnection between external devices and Mark V rack electronics\u003c\/li\u003e\n\u003cli\u003eCompatibility with redundant wiring configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Network and I\/O Interface Considerations\u003c\/h3\u003e\n\u003cp\u003eThe DS200DTBAG1AAA does not provide direct network communication functions. Its role is limited to physical signal termination and electrical distribution. In Mark V systems, communication processing and deterministic data exchange are handled by controller and communication modules.\u003c\/p\u003e\n\u003cp\u003eThe terminal board supports I\/O density expansion through organized field wiring interfaces. Proper terminal assignment, cable segregation, and grounding practices are required to maintain signal integrity between field devices and control electronics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200DTBAG1AAA contain onboard processing or firmware?\u003cbr\u003eA: No. The DS200DTBAG1AAA is a passive terminal board assembly. Signal monitoring and diagnostics are performed by connected Mark V processor and control boards.\u003c\/p\u003e\n\u003cp\u003eQ: What signal types can be connected to this terminal board?\u003cbr\u003eA: The board supports analog signals, digital 24 VDC signals, and trip solenoid related field connections according to the Mark V system wiring configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Does the board provide Ethernet or serial communication interfaces?\u003cbr\u003eA: No. The DS200DTBAG1AAA provides physical terminal connections only. Communication functions are managed by separate Mark V controller and communication modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DS200DTBAG1AAA in the designated GE Mark V rack position and verify mechanical alignment before securing the board.\u003c\/p\u003e\n\u003cp\u003eField wiring should be installed according to the Mark V wiring documentation. Separate low-level analog signal cables from high-current power and trip circuit wiring to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shields according to the system grounding design. Ensure terminal screws are properly secured and verify wire identification before applying field power.\u003c\/p\u003e\n\u003cp\u003eInspect terminal connections during maintenance activities for loose conductors, oxidation, or mechanical damage. Confirm compatibility with connected CPCA, LDCC, and other Mark V interface boards before replacement installation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44437225832536,"sku":"DS200DTBAG1AAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200DTBAG1A.jpg?v=1784797125","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ge-ds200dtbag1aaa-terminal-board-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}